DeviceXPlorer OPC Server DXP2007 series


Ver4.0.1.4 - 2008 Aug.
1240151 ALL The memory leak might occur when the string tags is accessed in simulation mode.
1240152 ALL The application error might be generated in communication processing with PLC.
1240153 ALL The application error might be generated by the checking processing of license information.
1240143 ALL It might take time to respond when asynchronize request is executed two or more times while the communication error.
1240137 ALL It is displayed, the project name is "Untitled" when starting.
1240140 ALL The change of the application name of DDE/SuiteLink doesn't become effective.
1240141 ALL If writing is executed through DDE/SuiteLink interface, CPU utilization might become higher.
1240142 ALL The application error might be generated when a specific click operation is done by the device view.


Ver4.0.1.3 - 2008 Feb.
1240121 MELSEC Fix the issue that the Message Error occurs when block access command is used.
1240122 MELSEC Fix the issue that the value of buffer memory (G) read of special unit is not appropriate.
1240125 SYSMAC Fix the issue that bank number accesses 0 even if other bank number is specified when extended data memory (EM) is accessed.
1240126 SYSMAC Fix the issue that the Message Error occurs when Timer and Counter (TC/CC)contact is read.
1240127 SYSMAC Fix the issue that the value can be written to byte-type tag (read only) from OPC client.
1240128 ALL Fix the issue that the error occurs when the value is written in hexadecimal number of the small letter in tag view.
1240129 MELSEC Fix the issue that the write processing failed when it communicates with ACPU in format 4.
1240131 MELSEC Fix the issue that NAK Receive Error occurs when QnACPU is selected.
1240132 MELSEC Fix the issue that the write value of word device is not appropriate when block access command is used.
1240133 ALL The start processing about minimization and task tray are improved.


Ver4.0.1.2 - 2007 Dec.
1240120 FA-M3 Fix the issue that the value is wrong in the continuous bit device read.
1240123 All Fix the issue that the handle leak occurs when Ethernet port open is error.


Ver4.0.1.1 - 2007 Oct.
1240110 KV All KV5000 series is supported (Supported KV-LE20V Protocol).
1240111 MICREX The write command of bit unit is supported.
1240100 ALL Fix the issue that the non-changed items is notified by DataChange event.
1240101 SYSMAC Fix the issue that the value is wrong, in the bit read of the word device.
1240102 MELSEC Fix the issue that "Auto Change Route" is wrong when it is saved, in the port dialog.
1240103 MELSEC Fix the issue that "Unit I/O No." in "Multiple CPU System" is wrong when it is saved, in the device dialog.
1240104 ALL Fix the issue that the error occurs when the value is written in hexadecimal number of the small letter, in tag view.
1240105 FA-M3 Fix the issue that the Message Error occurs when array-type tag of bit device is read.
1240106 HIDIC Fix the issue that the access point can be set exceeding the maximum value, when EH-CPU is selected.
1240107 MELSEC Fix the issue that the error don't occur, when the abnormal message is recieved in connecting FXCPU.
1240112 MODBUS
KV
FA-M3
SATELLITE
Fix the issue that the PLC device name for Connection Test is not appropriate.
1240114 ALL Fix the issue that the displaying such as message output is not appropriate, about the platform license.
1240116 FA-M3 Fix the issue that the Timer and Buffer Memory can be added to server, in using Asyncronous Access.
1240117 ALL Fix the issue that the error occurs, when "Find" function is used in the Diagnostics View.
1240115 ALL The restriction of demo version that can use only one device type (for example only "D" register) is removed.
1240118 ALL The method how to permute tag in Diagnostics View is improved.(in Tag Name order -> in Tag Path order)
----- ALL OPCClient.exe is updated. (Version 3.06)
----- ALL OPC Core Components 3.00 file is updated. (3.00.1.02)
1240108 ALL OPC Compliance Test 2.0.13 is passed. (DA2.05A 2.0.17/DA3.0 1.0.13)
1240113 MODBUS The configuration file of waveform module (type 2321) and multiple module (type 2306) of HIOKI 2300 series are added.


V4.0.0.1 - 2007 Jun.
1231220 ALL When the tag of simulation mode is enabled and its patturn is "Dummy", even the value that is out of range is written to tags with the scale conversion enabled.
1231221 ALL Every time the value of tag with the scale conversion enabled is read, time stamp and quality flag are updated.
1231220 ALL Changed to return S_OK when the item name was specified by IOPCBrowse::Browse.


DeviceXPlorer OPC Server Ver.3 series


Ver3.12 (Build3) - 2007 Mar.
1231209 ALL Improved the IOPCItemMgt::RemoveItems interface function.
------- ALL Passed OPC Compliance Test 2.00.12.1138(DA2.05A 2.00.15/DA3.0 1.00.11)


Ver3.12 (Build2) - 2006 Nov.
1231206 MELSEC Registerd items as "Z" in OPC Server, when they are registerd as device name "T", "C", "S", "E" from OPC Client.(Correspond Version 3.12 Build1)


Ver3.12 (Build1) - 2006 Nov.
1231203 ALL Add these following settings.
# Reject unregistered items (Reject access to unregistered items in OPC Server from OPC Client.)
# Hide system tag. (Do not show system tag on tag view.)
1231204 ALL Add the setting on tag dialog.
# Access right (set right to access from OPC Client.)
1231205 MELSEC Support Special Link(SB), Link Special Register(SW), Edge Relay(V), and Index Register(Z).


Ver3.11 (Build5) - 2006 May
1231128 ALL Changed to switch the simulation mode to Enabled/Disabled by changing the System tag $Simulate switched to ON/OFF.
1231138 ALL Changed to display the device name and group name in ascending order in the device view.
1231140 ALL Add to show the error code into OPC interface log
1231157 ALL Add the delay time setting in the serial port configuration to delay sending commands to PLC.
1231133 ALL Cannot use the serial port of COM10 and more.
1231134 ALL Modified to return expception error when called IOPCAsyncIO2::Refresh2
1231137 ALL Modified to be refused the AddItem method while openning the new device dialog
1231145 ALL Fix the issue not to update the Quality by communication error
1231146 ALL Fix the issue to stop updating display when much messages is put into LogView.
1231156 ALL Fix the issue that it may occur the application error when it is selected "Tag" in "Project" menu if the device does not exist
1231161 ALL Fix the issue that changine value is ignored by open/close scaling dialog
1231162 ALL When the value is out of the range of scale conversion, it will not be stored in the item.(Correspond Version 3.10 Build2-3.11 Build4)
1231163 ALL When simulating the array type tags of VT_I4, VT_UI4 and VT_R4, random values were returned even with the ramp simulation pattern specified.
1231164 ALL When browsing OPC Items with OPC Client, tags with the scale conversion enabled is filtered not by the VT_R8 but by the non scale converted data type.
1231147 ALL Changed to create log files with the date and file serial numbers (000 - 999). Also changed to set the maximum file size in MB (in previous version, in KB).
------- ALL Updated OPC Core Components 2.00 Files(2.00.2.30)
------- ALL Updated OPC DA Automation DLL Files(2.02.5.30)
------- ALL Passed OPC Compliance Test 2.00.10.1130(DA2.05A 2.00.13/DA3.0 1.00.9)


Ver3.11 (Build4) - 2005 Nov.
1231119 HIDIC Corresponded EHV-CPU


Ver3.11 (Build3) - 2005 Sep.
1231111 ALL Changed writing has an advantage over reading.(Correspond Version 3.10 Build2-3.11 Build2)


Ver3.11 (Build2) - 2005 July.
1231103 ALL Sometimes last item misses to be written when items that belong to different devices exist.(Correspond Version Ver3.01 Build1-Ver3.11 Build1)
1231105 ALL Added OPC Client name in OPC access log.

Ver3.11 (Build1) - 2005 May.
1231100 ALL Changed the install license authentication
1231102 ALL Changed the description of ProgID and service name to "DeviceXPlorer XXXXXX OPC Server".


Ver3.10 (Build3) - 2005 May.
1231064 ALL Changed the return NULL for IOPCItemProperties::LookupItemIDs and IOPCBrowse::GetProperties when idsuffix was referred.
1231065 ALL Memory leak occurs when tag monitor is executing.(Correspond Version 3.10 Build1/Build2)
1231067 ALL Event of KeepAlive (OnDataChange) is not notified when the item is invalidated.
1231069 ALL Memory leak occurs when OPCGroup that has inactive OPCItem is deleted.(Correspond Version 3.10 Build1/Build2)
1231071 ALL Array type tag of VT_I2 / VT_UI2 operate in the simulation mode of tag even if one of the device is set to priority.
1231072 FA-M3 Device range of L and W device is expanded to 8192 from 2048
1231073 ALL Changed the return value to OPC_E_INVALIDITEMID from OPC_E_UNKNOWNITEMID for IOPCBrowse::GetProperties when item could not be found.
------- ALL Updated OPC DA Automation DLL File (2.02.5.20)


Ver3.10 (Build2) - 2005 Feb.
1231040 ALL Improved the IOPCBrowseServerAddressSpace::ChangeBrowsePosition interface when it was specified OPC_BROWSE_TO.
1231047 ALL Supported BCD->BIN conversion with Array type data.
1231051 ALL Write process become slow when write failure occurred with multiple device configuration.
1231052 MELSEC Can not detect timeout on serial communication. (Correspond Version 3.10 Build1)
1231056 MELSEC Array tag's data type can not change to client requested data type when IOPCAsyncIO Read was executed. (Correspond Version 3.10 Build1)
1231057 ALL It is changed to return user definition value (0x00048000L) to ppErrors when a communication error occurs at the time of the Read.
1231058 ALL Device icon left connecting even if communication is finished after it changes to standing by when the communication configured redundant setting.
1231059 ALL An application error sometimes occurrs when log display paused and sorted the label.
1231060 MELSEC It sometimes fails in the copy of OpcRcw.Da.dll at the time of the installation.
1231062 ALL The date of the message in the log pane proceeds a day.
------- ALL Updated OPC Core Components 2.00 Files(2.00.2.20)
------- ALL Updated OPC DA Automation DLL Files(2.02.5.12)
------- ALL Passed OPC Compliance Test 2.00.7.1120(DA2.05A 2.00.8/DA3.0 1.00.3)
------- ALL Updated VB.NET Sample client (DotNetRcwSample)


Ver3.10 (Build1) - 2004 Oct.
1231014 ALL System information tag isn't added at the time of the device import
1231001 ALL Supported new tag type that is always uses in the simulation mode
1231000 ALL Supported OPCDA3.0 optional interface IOPCItemSamplingMgt
1231002 ALL Supported Multi Access Mode (Supported independent operation of ports and groups)
1231003 ALL The request queue for writing is canceled when write error occurred
1231004 ALL Send error occurs when baud rate is low on serial communication
1231006 ALL The maximum number of asynchronous requests modified 100 to 1000
1231008 ALL The port name during the communication is stored in the tag name "$Portname"
1231020 ALL Improved the ItemIO::WriteVQT interface function when communication error occurred
1231022 ALL Improved to hangs up in Ethernet port setting when the adaptor doesn't exist Ethernet
1231017 ALL The default type of the CPU is changed to QCPU
1231016 MELSEC EZSocket(include CPU Port and MELDAS)/GX Simulator communication are supported
1231007 MELSEC Supported intelligent unit buffer memory access
1231010 MELSEC The file register ZR is supported
1231011 MELSEC Improved that it becomes an error of accessing block 0 of the file register when the interface board is used
1231009 SYSMAC Supported Timer and Counter(current value and contact)


Ver3.00 (Build3) - 2004 Jun.
1230118 ALL OPC Server gave no response when it was edited or monitored after the new tag was imported
1230119 MELSEC Could not communicate with MELSEC(AnN/AnA/AnU/FX) by serial communication when station No or PC No was set more than 10


Ver3.00 (Build2) - 2004 Jun.
1230111 ALL Startup Tag file setting of Start Up(Tools menu -> Option) is not kept


Ver3.00 (Build1) - 2004 Feb. - Apr.
1230000 ALL Compatible with OPCDA3.0
------ ALL Renewal GUI (menu, toolbar, dialog or something)
------ ALL Monitor the status accessing from OPC Client
------ ALL Added the default simulation pattern
------ ALL Modified the tag registered operation
------ ALL Display the detail information and sort function of logged data is added
------ ALL Auto save function for logged information is added
------ ALL Supply the .NET Framework sample


Ver2.42 (Build7) - 2004 Feb.
1224258 ALL Fixed the tag registered automatically doesn't monitor the value
1224260 ALL Change the auto naming rule on automatically added
1224263 ALL Modified the action on poke error happened
1224266 ALL Modified to poke process when mixed word devices and double word devices
------ ALL Update OPC common files
1224259 MELSEC Fixed to register the invalid address for the tag under 32767 when auto-registration with 'ZR'
1224267 MELSEC Fixed to be not able to input network number in device dialog with interface board
1224262 FA-M3 Fixed to be not able to change COM port number


Ver2.42 (Build6) - 2003 Jul.
1224234 ALL Fixed to return invalid value for reading after poking to scale convert tag or BCD convert tag.
1224246 ALL Fixed to sometime occur memory leak when execute AsyncRead to string or array tags
1224250 ALL Modified IOPCItemProperties::LookupItemIDs interface action
1224254 ALL Modified Async2::Refresh2 interface action
1224253 ALL Modified to call IOPCDataCallback::OnCancelComplete after Async2::Cancel2
1224252 ALL Modified IOPCItemProperties::GetItemProperties interface action
1224239 FA-M3/
TOYOPUC
Fixed to occur error by Read/Write operation just after Additem
1224236 SYSMAC Fixed that the change of read span is not reflect on device dialog
1224237 SYSMAC Modified to be suited poke action on continuous access range


Ver2.42 (Build5) - 2003 May.
1224232 ALL Fixed to return error even when be successful with poking into array tag. (Bug of Ver2.42 Build4)
1224233 ALL Modified to generate the data-change event on completing poke action


Ver2.42 (Build4) - 2003 Apr.
1224226 ALL Fixed to be stopped automatic re-connection on TCP/IP Full-Passive communication
1224228 ALL Fixed to be not able to change the name of OPC Group Name on active from OPC Client


Ver2.42 (Build3) - 2003 Mar.
1224223 ALL Fixed to be not able to connect again after happening communication error on Ethernet. (Bug of Ver2.42 Build1 / Build2)


Ver2.42 (Build2) - 2003 Feb.
1224222 ALL Fixed to be not able to poke to Array tags. (Bug of Ver2.42 Build1)
1224224 MELSEC Modified SPIN button keeps disable


Ver2.42 (Build1) - 2003 Jan.
1224200 ALL Certificated compliance test - OPCDA 2.05A
1224203 ALL Expanded max of port from 64 to 128
1224204 ALL Modified to be able to select whether attached '$' mark with system tags
1224205 ALL Changed rule of tag name generation
1224206 ALL Added 'Simulate' in system tag
1224207 ALL Change menu resource
1224208 ALL Modified to idle time when Ethernet open error occurred
1224210 ALL Fixed to be not able to back when select Square Root in scaling
1224211 ALL Fixed to be not able to load normally if comments include ','
1224212 ALL Fixed to be shown the value '??' on monitor when array tag imported
1224213 ALL Fixed scaling configuration is not available while communicating
1224214 ALL Fixed bandwidth value is invalid
1224215 ALL Fixed to re-bind when open error occurred
1224218 MELSEC Fixed to be written '-1' if serial communication with AnN/FX CPU
1224216 FAM3
/SYSMAC
Fixed to be not shown ':U' on unsigned short tag
1224217 SYSMAC Fixed to be not shown ':R' on real tag
1224209 SYSMAC Modified bank range '0 - 28'
1224219 SYSMAC Modified EDIT button is disable with FINS port
------ SYSMAC Fixed available spin button in tag dialog
1224220 ALL Modified to be not as error while FINS communicating when sub code returned except '0' from FinsGateway


Ver2.41 (Build1) - 2002 Jul. - Oct.
------ ALL Fixed bandwidth will be invalid value
------ ALL Fixed to be happened memory leak when read/write operation with deactivate OPC group
------ ALL Windows XP compatible
------ ALL Run as windows service program
------ ALL Duplex communication port
------ ALL System information tag
------ ALL Poking from OPC Server window
------ ALL Auto Creating message files
------ ALL Fixed to leak memory on AsyncPoke() with string type
------ ALL Modified to be not able to access tag after poking abnormal value with variant type from VB
------ ALL Modified to be not able to get OPCItem properties of scale convert
------ FAM3 Supported Ethernet unit LE11-0T
------ SYSMAC Supported native communication of serial and Ethernet. (Not use FINS Gateway)
------ MELSEC On Ethernet communication, CPU monitoring timer was changed to 10 sec from 2 sec¨X
------ MELSEC Fixed to be able to access scale property for not configured tags


Ver2.30 (Build6 : MELSEC / Build4 : FAM3, SYSMAC / Build10 : TOYOPUC) - 2002 Aug.
------ ALL Modified to return exception with invalid server handle on SyncRead
------ SYSMAC Bank number of expanded EM to maximum 12
------ SYSMAC Fixed header title is out of position on device export


Ver2.30 (Build5) - 2002 May.
------ MELSEC Fixed to be fail on batch poke to bit device with MELSEC interface boards
------ MELSEC Scale conversion will be fail for negative value


Ver2.30 (Build4 : MELSEC / Build3 : FAM3, SYSMAC / Build9 : TOYOPUC) - 2002 Feb.
------ ALL Application error will be happened on Port dialog (Ethernet)
------ ALL Change to return normally when execute Read/Write operation while connecting Ethernet without OPC_QUALITY_COMM_FAILURE.
------ ALL Fixed header title is out of position on device export.


Ver2.30 (Build3) - 2001 Dec.
------ MELSEC Fixed to be happened application error when timeout error occurred on connecting MELSEC-Q/QnA Ethernet.
------ MELSEC Fix to register special relay 'SM' and special register 'SD'


Ver2.30 (Build2) - 2001 Aug.
------ ALL Supported with unsigned integer (VT_UI2 / VT_UI4)
------ ALL Supported with array type, VT_ARRAY : VT_BOOL / VT_I2 / VT_UI2 / VT_I4 / VT_UI4 / VT_R4
------ ALL Fixed to be poked the previous value of conversion to scaled tag
------ ALL IP address will be changed to invalid value when jump from device configuration dialog
------ MELSEC Supported MELSEC multi CPU system
------ MELSEC Supported CONTEC PC unit (PPC-CPU)
------ MELSEC Supported user setting on batch poke points
------ MELSEC
/FAM3
Supported to access bit device as real type tag
------ SYSMAC Supported to access 'D' as 'DM'
------ SYSMAC Modified to swap upper byte and lower byte of string tag


Ver2.24 (Build1) - 2001 Jan.
------ ALL Change Device dialog
------ ALL Added button to configuration the communication port on device dialog
------ ALL Modified to get BCD configuration on imported tag
------ ALL Certificated compliance test - OPCDA 1.0
------ ALL Modified OPCDAAuto.dll (Update 'OPCDAAuto.dll' because can't configure the Updaterate on Windows 2000)
------ FAM3 When using Binary communication on Ethernet, the poke operation to DWORD/REAL will be failed


Ver2.23 (Build1) - 2000 Oct.
------ ALL Fixed the retry function is executed an extra time
------ ALL Fixed to read the data abnormal when some device in some groups is registered for one group. (ex : Group1 <<-- UC24.D0 Ether.M0 MENT.W0...)
------ ALL Fixed the error checking routine of some OPC interface
------ ALL Fixed to return 'OPC_S_CLAMP' when written data to over size for string tags
------ ALL Standardize the declaration of static pattern for simulation function to 'dummy'
------ ALL the string tag for simulation mode is improved to be changed the value
------ ALL Fixed to be not able to store in task tray when starting with remote client
------ FAM3 Fixed to be not able to access to the device over 32768
------ MELSEC Standardize the declaration of 'random read' to 'block access'
------ MELSEC Fixed to not show the log message when accessing to bit type device
------ MELSEC Fixed to be set irregular string size when registering bit type tag in dialog
------ MELSEC Improve the random write size to 1024 when using MELSEC Interface board


Ver2.22 (Build1) - 2000 Jan.
------ SYSMAC OMRON SYSMAC OPC Server release
------ FAM3 YOKOGAWA FA-M3 OPC Server release
------ MELSEC Enable to select priority of thread and process
------ MELSEC Enable to access to other groups within executing much SyncRead operation
------ MELSEC Progress bar on import/export tag
------ MELSEC Progress bar on edit tag
------ MELSEC Open configuration dialog on Double click at Device name
------ MELSEC Communicate only displayed tags While monitoring on screen
------ MELSEC Store in task tray on minimize operation
------ MELSEC A display place of 'D', 'R', 'ER' change to 5
------ MELSEC Change find algorithm on registered item


Ver2.21 (Build1) - 2000 Feb.
------ MELSEC Supported random read operation
------ MELSEC Supported CPU port and LLT with MX-Links (SWnD5C-CSKP)
------ MELSEC Supported CC-Link Master Board (A80BD-J61BT11)
------ MELSEC Fixed disappear tips on task tray


Ver2.20 (Build3) - 1999 Dec.
------ MELSEC Fixed percentage of CPU is to 100 if OPCItem is continuously valid and invalid


Ver2.20 (Build2) - 1999 Nov.
------ MELSEC Fixed not release memory of string tag accessing


Ver2.20 (Build1) - 1999 Aug.
------ MELSEC Supported MELSEC-Qn Series
------ MELSEC Supported Bit position read in word device
------ MELSEC Supported String and BCD type
------ MELSEC Enabled to select configuration file on startup
------ MELSEC Enabled to select data type on tag edit
------ MELSEC Communication port dialog
------ MELSEC Enabled to select group level on import/export tag
------ MELSEC Support import/export function


Ver2.10 (Build2) - 1999 Aug.
------ MELSEC Fixed normally start without Administrator of WinNT


Ver2.10 (Build1) - 1999 Jul.
------ MELSEC Supported MELSEC Interface Board for personal computer
------ MELSEC Supported multiple LAN adapter
------ MELSEC Supported any COM port without limited
------ MELSEC Supported import/export function of tag
------ MELSEC Supported dump of communication log
------ MELSEC Supported dump of OPC interface access log
------ MELSEC Supported export log to text file
------ MELSEC Supported store to task tray
------ MELSEC Supported word access of bit device
------ MELSEC Supported user configuration of retry times on timeout
------ MELSEC Supported user configuration of packet size on batch reading
------ MELSEC The 'Type' in Tag View is changed from the Device name to the Data type
------ MELSEC Supported auto shutdown function
------ MELSEC Fixed stop bit is not available on serial communication


Ver2.00 (Build1) - 1999 Feb.
------ MELSEC Supported OPCDA2.0
------ MELSEC Deleted WORD SWAP selection
------ MELSEC Supported auto addition of item
------ MELSEC Enable to force shout down while client is connecting
------ MELSEC Supported continuous tag entry
------ MELSEC Supported Expand File Register
------ MELSEC Fixed application error on item removing

BACK