Forward |
This information is about bug or new function, and supplied for promoting user integration
|
| DeviceXPlorer OPC Server DXP2007 series |
| Release No. |
Target |
Contents |
| ------- |
------- |
[Bug Fix] |
| 1241151 |
ALL |
Improved the problem that log messages of DataChange Event are dumped after unadvise by Client in using Async Update Mode.(Target Version:4.2.0.1) |
| 1241152 |
ALL |
Improved the problem that application error occurs in using Import/Export wizard.(Target Version:4.2.0.1) |
| 1241153 |
ALL |
Improved the problem that the diagnostics icon color is discord with Quality flag in Diagnostics View. |
| 1241154 |
ALL |
Improved the problem that the list is sorted as bad order of Timestamp and Quality in Diagnostics View. |
| 1241155 |
ALL |
Improved the problem that items of Watch View increases by changing language. |
| 1241156 |
ALL |
Improved the problem that logs of Message View are cleared by changing language. |
| 1241150 |
MELSEC |
Improved the problem that the communication is failed with multi-drop link of serial communication. |
| 1241157 |
MELSEC |
Improved the problem that the log of warning is dumped about EZSocket group setting when opening the project file of before V4.2.(Target Version:4.2.0.1) |
| 1241158 |
MELSEC |
Improved the problem that the setting of EZSocket dialog is deleted when opening the project file of before V4.2.(Target Version:4.2.0.1) |
| 1241159 |
OPC CLIENT*1 |
Improved the problem that the OPC Group is set as InActive in using SyncRead(Cache) for Read I/F. |
| 1241160 |
OPC CLIENT*1 |
Improved the problem that the dead-lock may occur depending on target server specification if complete event is received before returning asynchronous calling. |
| 1241161 |
OPC CLIENT*1 |
Improved the problem that properties are not got if target server return error in browsing item. |
| Release No. |
Target |
Contents |
| ------- |
------- |
[New Function] |
| 1241095 |
ALL |
Corresponded to Windows 7. |
| 1241096 |
ALL |
Corresponded to Chinese OS and Simplified Chinese. |
| 1241108 |
ALL |
Added the filter of string in Message View. |
| 1241109 |
ALL |
Added the function to multi access for Sync process and Async process. |
| 1241110 |
ALL |
Added the function to minimize the message packets for writing to PLC. |
| 1241112 |
ALL |
Added the function to change cycle and max-value in "Simulation Mode". |
| 1241113 |
ALL |
Added the function to change and clear Serial Number of Licence. |
| 1241114 |
ALL |
Added the viewer for Array Tag. |
| 1241115 |
ALL |
Added the fuction to sort by tag in exporting to CSV file. |
| 1241116 |
ALL |
Added the function to set transmission delay in Ethernet Connections. |
| 1241117 |
ALL |
Added the function to change Time-out of Non-Blocking Mode in Ethernet. |
| 1241118 |
ALL |
Expanded the maximum Serial-port number which can set to 256 from 32. |
| 1241119 |
ALL |
Improve the communication processing with tags which have Extended Tag Name Specification. |
| 1241120 |
ALL |
Added the shortcut keys (Device Monitor, Write Value to Tag and so on). |
| 1241121 |
ALL |
Added the function to copy the logs in Message View to the clip board. |
| 1241122 |
ALL |
Added the function to return cache value when communication error occurred. |
| 1241097 |
SIMATIC |
Corresponded to Siemens SIMATIC S7 Ethernet Conncetion. |
| 1241098 |
MELSEC |
Corresponded to MELSEC-L series and FX3U-ENET-L. |
| 1241099 |
MELSEC |
Added the function to access Buffer memory in EZSocket connection. |
| 1241100 |
MELSEC |
Corresponded to Extended link register "W" in Interface Board connection. |
| 1241101 |
MELSEC |
Corresponded to PCI Express Interface Board. |
| 1241102 |
MELSEC |
Corresponded to State Device "S" in MELSEC-FX series. |
| 1241107 |
FANUC |
Corresponded to FAUNC CNC/PMC Data Window Library (FOCAS 1/2). |
| 1241103 |
MICREX |
Corresponded to MICREX-F series.. |
| 1241104 |
OPC CLIENT*1 |
Corresponded to OPC-DA3.0. |
| 1241105 |
OPC CLIENT*1 |
Added the delay time to access tag after AddItem, when you select "Synchronous Read(Cache)" in Read I/F. |
| 1241106 |
OPC CLIENT*1 |
Corresponded to Group Deadband in OPC-DA2.0. |
| ------- |
------- |
[Change Specification] |
| 1241123 |
ALL |
All settings are saved in one project file. (Previously, saved in some project files.) |
| 1241124 |
ALL |
Project file is saved to "My Document"Folder as default. |
| 1241126 |
ALL |
MSXML6 is not installed in DXP2007 x86 edition. (Previously, installed.) |
| ------- |
------- |
[Bug Fix] |
| 1241127 |
ALL |
Improved the problem that DXP2007 can't recognize HASP key. |
| 1241128 |
ALL |
Improved the problem that DXP2007 may not access PLC uncommonly when OPC Client calls AddGroup function immediately after DXP2007 started with COM. |
| 1241129 |
ALL |
Improved the problem that DXP2007 can't write values to Array Type item by DDE or SuiteLink interface.(Target Version:4.0.1.5 to 4.1.2.4) |
| 1241132 |
ALL |
Improved the problem that the Timestamps is not changed by writing. |
| 1241133 |
ALL |
Improved the problem that old Timestamp is notified by DataChange event of ASyncIO2::Refresh. |
| 1241134 |
ALL |
Improved the problem that the DataChange event occur twice by ASyncIO2::Refresh. |
| 1241135 |
ALL |
Improved the problem that the Quality of Tags may be "Waiting for Initial data" in Async Update Mode. |
| 1241136 |
ALL |
Improved the problem that DXP2007 run as demo mode when it started by Non-Administrator in UAC available. |
| 1241137 |
ALL |
Improved the problem that the DataChange event by ASyncIO2::Refresh(Device) is delayed.(Target Version:4.1.2.4) |
| 1241138 |
ALL |
Improved the problem that the write value of "Octal Text" or "Decimal Text" may be incorrected. |
| 1241143 |
ALL |
Improved the problem that Common/Project Properties may be changed uncommonly when language is changed. |
| 1241149 |
ALL |
Improved the problem that DataChange event occurs twice or more times at first timming. |
| 1241130 |
MELSEC |
Improved the problem that memory leak may occur by writing values by Block Access. |
| 1241142 |
MELSEC |
Improved the problem that DXP2007 can not access X/Y device properly in the FX series. |
| 1241144 |
MELSEC |
Improved the problem that the error may occur when writing value to Random Access Buffer. |
| 1241145 |
MELSEC |
Improved the problem that the error may occur when writing value to Timer or Count device in Non Block Access. |
| 1241148 |
TOYOPUC |
Changed data type of tag which has non extended specification to USHORT from SHORT. |
| 1241131 |
FA-M3 |
Improved the problem that DXP2007 may access incorrect address in Asynchronous Access Mode.(Target Version:4.1.0.1 to 4.1.2.4) |
| 1241139 |
AB |
Improved the problem that "Message Error" may occur when writing to plurals tags. |
| 1241140 |
MP |
Improved the problem that commucation may stop uncommonly in MEMOBUS-BIN Protocol. |
| 1241146 |
FP |
Improved the problem that error may occur when writing value to bit-device as Non bool type. |
| Release No. |
Target |
Contents |
| ------- |
------- |
[New Function] |
| 1241071 |
ALL |
Added the function which can select connection mode either "Non-Blocking Mode" or "Blocking Mode" at Ethernet port settings. (Ver4.0.0.1-Ver4.1.1.1:"Blocking Mode". Ver4.1.1.1:"Non-Blocking Mode") |
| 1241073 |
MODBUS |
Added the function which can change the cardinal number of address into "0". (default is "1"). |
| ------- |
------- |
[Change Specification] |
| 1241074 |
ALL |
In the case which the communication time for access PLC takes time than OPC UpdateRate, the next communication is started without waiting time after the communication end. (Previously, communication is started at the timing of the next update period.) |
| 1241075 |
ALL |
Data type of SystemTag which has VT_I2 or VT_I4 data type is changed into VT_UI4. |
| 1241076 |
MODBUS |
Offset and Module ID of Group Dialog is reflected to tag's device address. |
| 1241077 |
OPC CLIENT*1 |
Waiting time for reconnecting with access OPC Server is set when DXP2007 received SHUTDOWN notification from access OPC server. |
| ------- |
------- |
[Bug Fix] |
| 1241072 |
ALL |
Improved the problem which application error may occur uncommonly by repeating adding and removing groups or tags continually by client. |
| 1241078 |
ALL |
Improved the problem that DataChange event is late for one scan time in validating "Multi Access Mode" and "Async Update Mode". |
| 1241079 |
ALL |
Improved the problem that DXP2007 doesn't respond uncommonly when OPC client runs AddGroup and RemoveGroup at the same timing. |
| 1241080 |
ALL |
Improved the problem that DXP2007 is not put in Task Tray at the timing of OS startup and User logon. |
| 1241081 |
ALL |
Improved the problem which can not save the device and port setting uncommonly after using Redundant Communication. |
| 1241082 |
ALL |
Improved the function of "Auto Message Saving" for reflecting the setting in the timing finishing the content change of file path of saving message. |
| 1241083 |
ALL |
Improved the function of "Auto Message Saving" for saving log which outputted in the timing of startup. |
| 1241084 |
MELSEC |
Improved the problem which can not save the setting of EZSocket when validating UAC in Windows Vista. |
| 1241085 |
MELSEC |
Improved the problem which can not access Extended File Register ( over ZR32768 ) in connecting with GXSimulator by EZSocket. |
| 1241086 |
MELSEC |
Improved the problem which can not set connecting parameter of CPU built-in Ethernet unit when specified CPU TYPE "QnU" in EZSocket setting . |
| 1241087 |
MODBUS |
Improved the problem which access incorrect address when the Offset (or Module ID) is set for tag by MODBUS group dialog. |
| 1241088 |
TOYOPUC |
Improved the problem that error of "Bad Message" occurs when using "Random Read Command" for accessing many points over 512. |
| 1241092 |
TOYOPUC |
Improved the problem that error of "Bad Message" occurs when accessing bool tag of bit device by "Random Read Command" in CPU Communication DLL. |
| 1241089 |
OPC CLIENT*1 |
Improved the problem that item error occurs when recovering the communication after using Redundant Communication. |
| 1241090 |
OPC CLIENT*1 |
Improved the problem that can not detect disconnection with access OPC Server in using Read I/F "Asynchronous Advise". |
| 1241093 |
OPC CLIENT*1 |
Improved the problem that can not register dynamic tags with access OPC Server in using Read I/F "Asynchronous Advise". |
| 1241091 |
ALL |
Improved the problem of C++ sample program "VcSampleOpc" which doesn't release reference of COM interface. |
| Release No. |
Target |
Contents |
| 1241055 |
ALL |
Expanded the maximum port number which can create to 256 from 128. |
| 1241056 |
ALL |
Added the function to write $Status flag of System tag in simulation mode. |
| 1241057 |
ALL |
Added the function to change the updaterate of Device Monitor. |
| 1241059 |
ALL |
Improved the problem that memory leak and commucation stop may occur by registering the plural same tags and the problem that communication stop may occur by high speed changing of the active state (Active/InActive). (Target Version:4.1.0.1 and 4.1.1.1) |
| 1241060 |
ALL |
Improved the received message judgment process to check more closely whether the received message is the message which expected or not. |
| 1241061 |
ALL |
Improved the problem that the other client may get mistake data when the one client disconnects in the environment which multi clients connect. |
| 1241063 |
MELSEC |
Improved the problem that the open error occurs when connect GX Simulator of QnUCPU. |
| 1241064 |
MELSEC |
Improved the problem of writing the mistaken address when write bit device in serial connection of FX-CPU. |
| 1241065 |
ALL |
Improved the problem that the change of system file is not saved when validating UAC in Windows Vista. (Target Version:4.1.0.1 and 4.1.1.1) |
| 1241068 |
ALL |
With Ethernet TCP/IP, improved that server wait long time to recognize Open Failure. |
| 1241070 |
OPC CLIENT*1 |
Improved the memory leak in the reading of array tag. |
| 1241067 |
ALL |
Improved the memory leak of C++ sample program "VcSampleOpc". |
| 1241069 |
ALL |
Improved sample program "VB6DAautoSample". |
| Release No. |
Target |
Contents |
| 1241050 |
ALL |
Added the function to change max count of async writing request. |
| 1241054 |
OPC CLIENT*1 |
Added the filter of string type and double type in item browse dialog. |
| 1241038 |
ALL |
Improved the problem that UpdateException error occurs when items are omitted deactivating and are deleted. |
| 1241040 |
ALL |
Improved the problem that it is not able to exit forcibly in connecting from clients. |
| 1241041 |
ALL |
Improved to problem that the version provided in IOPCServer is not correct. |
| 1241045 |
ALL |
Improved to ignore record of comma in CSV import. |
| 1241046 |
ALL |
Improved to combine records for device or port in CSV export. |
| 1241049 |
ALL |
Improved the problem of having application errors with copying tag between other device type. |
| 1241042 |
Shared Memory |
Improved to problem of outputting log as Communication Data Message. |
| 1241048 |
OPC CLIENT*1 |
Improved about outputting log messages and quality flags. |
| 1241052 |
OPC CLIENT*1 |
Improved the problem of failure of getting type information of tag value in browsing and creating tags automatically. |
| 1241053 |
OPC CLIENT*1 |
Improved the problem of reading items that is failed adding items. |
| Release No. |
Target |
Contents |
| 1241034 |
------ |
Released new models.
- PANASONIC FP series
- YASKAWA MP series
- Rockwell AB ControlLogix series
- OPC CLIENT*1
- Shared Memory |
| 1241002 |
MELSEC |
Added the function to access more than one PLC register by dynamic tags. |
| 1241005 |
ALL |
Corresponded to Windows Server 2008. |
| 1241006 |
MELSEC |
With Ethernet or Serial, corresponded to extended data register and extended link register. |
| 1241016 |
ALL |
Corresponded to Windows x64 Edition. |
| 1241018 |
ALL |
Added the function to change languages while running. |
| 1241025 |
ALL |
With diagnostics view, added the function to write tag value and drag-and-drop tag name. |
| 1241000 |
MELSEC |
Improved the problem of receiving PREVIOUS response from PLC for NEXT command, immediately after PREVIOUS command became timeout error. |
| 1241004 |
ALL |
With redundant communication, improved the problem of switching frequently the communication line when more than one OPCGroup access the same device. |
| 1241007 |
FANUC |
Improved the problem of switching frequently the quality of tag when the communication error occurs. |
| 1241008 |
ALL |
Improved the problem of having application errors with conversion of project. |
| 1241009 |
ALL |
Improved the problem of getting incorrect values when multi-byte character is written in shared memory tag of SYSTEM device. |
| 1241010 |
MICREX |
Improved the problem of failure of writing value for array tag. |
| 1241012 |
ALL |
Improved the problem of waiting for the end until the timeout is complete, when OPC client terminates while the communication error occurs. |
| 1241014 |
ALL |
In case of service application mode, improved the impossibility to communicate from OPC client when the user logs off Windows. |
| 1241015 |
ALL |
Improved the impossibility to save dynamic tags to project file, when the setting of "Save Unknown Item" is valid. |
| 1241022 |
TOYOPUC |
With TOYOPUC communication DLL, improved the problem of having application errors when the PLC communication starts without the DLL. |
| 1241024 |
ALL |
With diagnostics view, improved the problem of considering error by disagreement of input character, capital letter or small letter. |
| 1241026 |
SYSMAC |
With FinsGateway, Improved the impossibility to reflect the configuration of "Timeout". |
| 1241030 |
ALL |
Upgraded the function of OPC sample client. |
| 1241033 |
SYSMAC |
With Serial, changed to display the PLC communication message by ASCII format. |
| 1241035 |
ALL |
Improved the problem of having application errors with pushing the finish button when making newly the device or the port on the way. |
| 1241017 |
ALL |
Improved the problem which the characters of System tag "$PortName" may be garbled and the problem which application error may occur at the end of application by repeating monitor of the System tag "$PortName". |
| Release No. |
Target |
Contents |
| 1240147 |
MELSEC |
Supported CPU with built-in Ethernet(QnUDEHCPU) and Processing CPU(Q02PHCPU / Q06PHCPU).
|
| 1240158 |
ALL |
Supported LONGLONG type(64-bit signed intenger), ULONGLONG type(64-bit unsigned intenger) and DOUBLE type(64-bit real number). |
| 1240174 |
ALL |
Improved the problem that connection test right after changing port was done at the former port in the device dialog. |
| 1240175 |
SYSMAC |
Improved the communication error occured when setting CPU type C series during connecting FinsGateway. |
| 1240178 |
ALL |
Improved the problem of having incorrect writings which repeat a same patterned letter strings when writing on PLC divided the letter strings data of the numerical form(binary / octal / decimal / hexadecimal), into some packets. |
| 1240179 |
MELSEC |
Improved the problem that 'T' or 'C' became 'S' and 'E' became 'Z' as a name of devices by item registration processing from OPC Client. |
| 1240180 |
SATELLITE |
Improved the problem that is getting incorrect read values of the letter strings data of the numerical form(binary / octal / decimal). |
| 1240181 |
MELSEC |
Improved the problem of the impossibility about changing to another type of port. |
| 1240183 |
HIDIC MICREX |
Improved the problem of having application errors with a process of batch writing to several tags. |
| 1240184 |
TOYOPUC |
With Ethernet, improved the problem that having incorrect retrieved bit devices using Random Read Command. |
| 1240185 |
TOYOPUC |
With Ethernet, improved the problem of having a sign of '0' for an error code, when receiving NAK responses. |
| 1240187 |
TOYOPUC |
With Ethernet, improved the problem of recieve time out after recieving NAK responses, communicating multiple hierarchical link. |
| 1240190 |
MODBUS |
Improved the problem that it always writes the value of '0' to the tag of 32bit datatype (LONG / ULONG / REAL) when using Word Swap function. |
| 1240191 |
ALL |
About DDE/SuiteLink, improved the problem of reading the value of Write Only tag. |
| 1240176 |
HIDIC SATELLITE |
Changed to be able to transmit initialized command every time opening the port. |
| 1241037 |
MODBUS |
Improved the problem of failure of writing value in tag which is over 4 byte data type such as Long when the setting of Word Swap is valid in Modbus Protocol. |
| Release No. |
Target |
Contents |
| 1240130 |
MELSEC |
With Ethernet, about FXCPU, improved the process of accessing to I/O Relay(X/Y) |
| 1240138 |
MELSEC |
With Ethernet, about FXCPU, improved the maximum access points. |
| 1240139 |
MELSEC |
With Ethernet or Serial, when QnACPU is selected, only A series units could be displayed in the list of intelligent units in the group dialog. This problem is improved. |
| 1240143 |
ALL |
Improved the response time problem when having a communication error and requesting an asynchronous writing several times. |
| 1240144 |
MELSEC |
With Ethernet or Serial, about FXCPU, improved the problem of the OPC clients’ adding unappropriate items. |
| 1240145 |
MELSEC |
With Serial, improved the problem of having application errors when writing into Extend File Register(ER/ZR). |
| 1240146 |
MELSEC |
With EZSocket, about AnUCPU, Improved the process of accessing to Extend File Register(ER). |
| 1240148 |
MELSEC |
With Serial, about AnUCPU, the process of accessing to Extend File Register(ER) is bad. |
| 1240149 |
ALL |
With Ethernet, improved the problem of displaying '-1’ as an error code when the open error happens. |
| 1240150 |
ALL |
Improved the impossibility to get the item starting values of shared memory mode. |
| 1240156 |
ALL |
Improved the application errors caused from changing port relation with the device. |
| 1240157 |
ALL |
Improved the application errors caused from adding, removing and setting items working with PLC. |
| 1240163 |
ALL |
About DDE/SuiteLink, Improved the update rate problem. |
| 1240166 |
ALL |
Improved the situation that OPC clients might not be able to get browse information when starting server by COM request. |
| 1240167 |
ALL |
Improved the problem of having application errors with the diagnostics view. |
| 1240170 |
MELSEC |
Improved the problem of being ZERO as the upper word when writing into LONG type tag related with Extend File Register. |
| 1240172 |
ALL |
Improved the problem of unreturning from a busy state when writing more than 65,535 at one request. |
| 1240160 |
ALL |
Supported batch writing about DDE/SuiteLink. |
| 1240161 |
ALL |
Changed the value of boolean item from 255 to 1 about DDE/SuiteLink. |
| 1240173 |
ALL |
Improved the displaying process about message view. |
| Release No. |
Target |
Contents |
| 1240151 |
ALL |
Fix the issue that the memory leak might occur when the string tags is accessed in simulation mode. |
| 1240152 |
ALL |
Fix the issue that the application error might occur in communication processing with PLC. |
| 1240153 |
ALL |
Fix the issue that the application error might occur by the checking processing of license information. |
| 1240143 |
ALL |
Fix the issue that it might take time to respond when asynchronize request is executed two or more times while the communication error. |
| 1240137 |
ALL |
Fix the issue that it is displayed, the project name is "Untitled" when starting. |
| 1240140 |
ALL |
Fix the issue that the change of the application name of DDE/SuiteLink doesn't become effective. |
| 1240141 |
ALL |
Fix the issue that CPU utilization might become higher if writing is executed through DDE/SuiteLink interface. |
| 1240142 |
ALL |
Fix the issue that the application error might occur when a specific click operation is done by the device view. |
| Release No. |
Target |
Contents |
| 1240121 |
MELSEC |
Fix the issue that the Message Error occurs when block access command is used. |
| 1240122 |
MELSEC |
Fix the issue that the value of buffer memory (G) read of special unit is not appropriate. |
| 1240125 |
SYSMAC |
Fix the issue that bank number accesses 0 even if other bank number is specified when extended data memory (EM) is accessed. |
| 1240126 |
SYSMAC |
Fix the issue that the Message Error occurs when Timer and Counter (TC/CC)contact is read. |
| 1240127 |
SYSMAC |
Fix the issue that the value can be written to byte-type tag (read only) from OPC client. |
| 1240128 |
ALL |
Fix the issue that the error occurs when the value is written in hexadecimal number of the small letter in tag view. |
| 1240129 |
MELSEC |
Fix the issue that the write processing failed when it communicates with ACPU in format 4. |
| 1240131 |
MELSEC |
Fix the issue that NAK Receive Error occurs when QnACPU is selected. |
| 1240132 |
MELSEC |
Fix the issue that the write value of word device is not appropriate when block access command is used. |
| 1240133 |
ALL |
The start processing about minimization and task tray are improved. |
| Release No. |
Target |
Contents |
| 1240120 |
FA-M3 |
Fix the issue that the value is wrong in the continuous bit device read. |
| 1240123 |
All |
Fix the issue that the handle leak occurs when Ethernet port open is error. |
| Release No. |
Target |
Contents |
| 1240110 |
KV |
All KV5000 series is supported (Supported KV-LE20V Protocol). |
| 1240111 |
MICREX |
The write command of bit unit is supported. |
| 1240100 |
ALL |
Fix the issue that the non-changed items is notified by DataChange event. |
| 1240101 |
SYSMAC |
Fix the issue that the value is wrong, in the bit read of the word device. |
| 1240102 |
MELSEC |
Fix the issue that "Auto Change Route" is wrong when it is saved, in the port dialog. |
| 1240103 |
MELSEC |
Fix the issue that "Unit I/O No." in "Multiple CPU System" is wrong when it is saved, in the device dialog. |
| 1240104 |
ALL |
Fix the issue that the error occurs when the value is written in hexadecimal number of the small letter, in tag view. |
| 1240105 |
FA-M3 |
Fix the issue that the Message Error occurs when array-type tag of bit device is read. |
| 1240106 |
HIDIC |
Fix the issue that the access point can be set exceeding the maximum value, when EH-CPU is selected. |
| 1240107 |
MELSEC |
Fix the issue that the error don't occur, when the abnormal message is recieved in connecting FXCPU. |
| 1240112 |
MODBUS KV FA-M3 SATELLITE |
Fix the issue that the PLC device name for Connection Test is not appropriate. |
| 1240114 |
ALL |
Fix the issue that the displaying such as message output is not appropriate, about the platform license. |
| 1240116 |
FA-M3 |
Fix the issue that the Timer and Buffer Memory can be added to server, in using Asyncronous Access. |
| 1240117 |
ALL |
Fix the issue that the error occurs, when "Find" function is used in the Diagnostics View. |
| 1240115 |
ALL |
The restriction of demo version that can use only one device type (for example only "D" register) is removed. |
| 1240118 |
ALL |
The method how to permute tag in Diagnostics View is improved.(in Tag Name order -> in Tag Path order) |
| ----- |
ALL |
OPCClient.exe is updated. (Version 3.06) |
| ----- |
ALL |
OPC Core Components 3.00 file is updated. (3.00.1.02) |
| 1240108 |
ALL |
OPC Compliance Test 2.0.13 is passed. (DA2.05A 2.0.17/DA3.0 1.0.13) |
| 1240113 |
MODBUS |
The configuration file of waveform module (type 2321) and multiple module (type 2306) of HIOKI 2300 series are added. |
| Release No. |
Target |
Contents |
| 1231220 |
ALL |
When the tag of simulation mode is enabled and its patturn is "Dummy", even the value that is out of range is written to tags with the scale conversion enabled. |
| 1231221 |
ALL |
Every time the value of tag with the scale conversion enabled is read, time stamp and quality flag are updated. |
| 1231220 |
ALL |
Changed to return S_OK when the item name was specified by IOPCBrowse::Browse. |
| DeviceXPlorer OPC Server Ver.3 series |
| |
Ver3.12 (Build3) - 2007 Mar. |
| |
Ver3.12 (Build2) - 2006 Nov. |
| 1231206 |
MELSEC |
Registerd items as "Z" in OPC Server, when they are registerd as device name "T", "C", "S", "E" from OPC Client.(Correspond Version 3.12 Build1) |
| |
Ver3.12 (Build1) - 2006 Nov. |
| 1231203 |
ALL |
Add these following settings.
# Reject unregistered items (Reject access to unregistered items in OPC Server from OPC Client.)
# Hide system tag. (Do not show system tag on tag view.) |
| 1231204 |
ALL |
Add the setting on tag dialog.
# Access right (set right to access from OPC Client.) |
| 1231205 |
MELSEC |
Support Special Link(SB), Link Special Register(SW), Edge Relay(V), and Index Register(Z). |
| |
Ver3.11 (Build5) - 2006 May |
| 1231128 |
ALL |
Changed to switch the simulation mode to Enabled/Disabled by changing the System tag $Simulate switched to ON/OFF. |
| 1231138 |
ALL |
Changed to display the device name and group name in ascending order in the device view. |
| 1231140 |
ALL |
Add to show the error code into OPC interface log |
| 1231157 |
ALL |
Add the delay time setting in the serial port configuration to delay sending commands to PLC. |
| 1231133 |
ALL |
Cannot use the serial port of COM10 and more. |
| 1231134 |
ALL |
Modified to return expception error when called IOPCAsyncIO2::Refresh2 |
| 1231137 |
ALL |
Modified to be refused the AddItem method while openning the new device dialog |
| 1231145 |
ALL |
Fix the issue not to update the Quality by communication error |
| 1231146 |
ALL |
Fix the issue to stop updating display when much messages is put into LogView. |
| 1231156 |
ALL |
Fix the issue that it may occur the application error when it is selected "Tag" in "Project" menu if the device does not exist |
| 1231161 |
ALL |
Fix the issue that changine value is ignored by open/close scaling dialog |
| 1231162 |
ALL |
When the value is out of the range of scale conversion, it will not be stored in the item.(Correspond Version 3.10 Build2-3.11 Build4) |
| 1231163 |
ALL |
When simulating the array type tags of VT_I4, VT_UI4 and VT_R4, random values were returned even with the ramp simulation pattern specified. |
| 1231164 |
ALL |
When browsing OPC Items with OPC Client, tags with the scale conversion enabled is filtered not by the VT_R8 but by the non scale converted data type. |
| 1231147 |
ALL |
Changed to create log files with the date and file serial numbers (000 - 999). Also changed to set the maximum file size in MB (in previous version, in KB). |
| ------- |
ALL |
Updated OPC Core Components 2.00 Files(2.00.2.30) |
| ------- |
ALL |
Updated OPC DA Automation DLL Files(2.02.5.30) |
| ------- |
ALL |
Passed OPC Compliance Test 2.00.10.1130(DA2.05A 2.00.13/DA3.0 1.00.9) |
| |
Ver3.11 (Build4) - 2005 Nov. |
| 1231119 |
HIDIC |
Corresponded EHV-CPU |
| |
Ver3.11 (Build3) - 2005 Sep. |
| 1231111 |
ALL |
Changed writing has an advantage over reading.(Correspond Version 3.10 Build2-3.11 Build2) |
| |
Ver3.11 (Build2) - 2005 July. |
|
1231103 |
ALL |
Sometimes last
item misses to be written when items that belong to
different devices exist.(Correspond Version Ver3.01
Build1-Ver3.11 Build1) |
|
1231105 |
ALL |
Added OPC Client
name in OPC access log. |
| |
Ver3.11 (Build1) - 2005 May. |
| 1231100 |
ALL |
Changed the install license authentication |
| 1231102 |
ALL |
Changed the description of ProgID and service name to "DeviceXPlorer
XXXXXX OPC Server". |
| |
Ver3.10 (Build3) - 2005 May. |
| 1231064 |
ALL |
Changed the return NULL for IOPCItemProperties::LookupItemIDs and IOPCBrowse::GetProperties when idsuffix was referred. |
| 1231065 |
ALL |
Memory leak occurs when tag monitor is executing.(Correspond Version 3.10 Build1/Build2) |
| 1231067 |
ALL |
Event of KeepAlive (OnDataChange) is not notified when the item is invalidated. |
| 1231069 |
ALL |
Memory leak occurs when OPCGroup that has inactive OPCItem is deleted.(Correspond Version 3.10 Build1/Build2) |
| 1231071 |
ALL |
Array type tag of VT_I2 / VT_UI2 operate in the simulation mode of tag even if one of the device is set to priority. |
| 1231072 |
FA-M3 |
Device range of L and W device is expanded to 8192 from 2048 |
| 1231073 |
ALL |
Changed the return value to OPC_E_INVALIDITEMID from OPC_E_UNKNOWNITEMID for IOPCBrowse::GetProperties when item could not be found. |
| ------- |
ALL |
Updated OPC DA Automation DLL File (2.02.5.20) |
|
Ver3.10 (Build2) - 2005 Feb. |
| 1231040 |
ALL |
Improved the IOPCBrowseServerAddressSpace::ChangeBrowsePosition interface when it was specified OPC_BROWSE_TO. |
| 1231047 |
ALL |
Supported BCD->BIN conversion with Array type data. |
| 1231051 |
ALL |
Write process become slow when write failure occurred with multiple device configuration. |
| 1231052 |
MELSEC |
Can not detect timeout on serial communication. (Correspond Version 3.10 Build1) |
| 1231056 |
MELSEC |
Array tag's data type can not change to client requested data type when IOPCAsyncIO Read was executed. (Correspond Version 3.10 Build1) |
| 1231057 |
ALL |
It is changed to return user definition value (0x00048000L) to ppErrors when a communication error occurs at the time of the Read. |
| 1231058 |
ALL |
Device icon left connecting even if communication is finished after it changes to standing by when the communication configured redundant setting. |
| 1231059 |
ALL |
An application error sometimes occurrs when log display paused and sorted the label. |
| 1231060 |
MELSEC |
It sometimes fails in the copy of OpcRcw.Da.dll at the time of the installation. |
| 1231062 |
ALL |
The date of the message in the log pane proceeds a day. |
| ------- |
ALL |
Updated OPC Core Components 2.00 Files(2.00.2.20) |
| ------- |
ALL |
Updated OPC DA Automation DLL Files(2.02.5.12) |
| ------- |
ALL |
Passed OPC Compliance Test 2.00.7.1120(DA2.05A 2.00.8/DA3.0 1.00.3) |
| ------- |
ALL |
Updated VB.NET Sample client (DotNetRcwSample) |
|
Ver3.10 (Build1) - 2004 Oct. |
| 1231014 |
ALL |
System information tag isn't added at the time of the device import |
| 1231001 |
ALL |
Supported new tag type that is always uses in the simulation mode |
| 1231000 |
ALL |
Supported OPCDA3.0 optional interface IOPCItemSamplingMgt |
| 1231002 |
ALL |
Supported Multi Access Mode (Supported independent operation of ports and groups) |
| 1231003 |
ALL |
The request queue for writing is canceled when write error occurred |
| 1231004 |
ALL |
Send error occurs when baud rate is low on serial communication |
| 1231006 |
ALL |
The maximum number of asynchronous requests modified 100 to 1000 |
| 1231008 |
ALL |
The port name during the communication is stored in the tag name "$Portname" |
| 1231020 |
ALL |
Improved the ItemIO::WriteVQT interface function when communication error occurred |
| 1231022 |
ALL |
Improved to hangs up in Ethernet port setting when the adaptor doesn't exist Ethernet |
| 1231017 |
ALL |
The default type of the CPU is changed to QCPU |
| 1231016 |
MELSEC |
EZSocket(include CPU Port and MELDAS)/GX Simulator communication are supported |
| 1231007 |
MELSEC |
Supported intelligent unit buffer memory access |
| 1231010 |
MELSEC |
The file register ZR is supported |
| 1231011 |
MELSEC |
Improved that it becomes an error of accessing block 0 of the file register when the interface board is used |
| 1231009 |
SYSMAC |
Supported Timer and Counter(current value and contact) |
|
Ver3.00 (Build3) - 2004 Jun. |
| 1230118 |
ALL |
OPC Server gave no response when it was edited or monitored after the new tag was imported |
| 1230119 |
MELSEC |
Could not communicate with MELSEC(AnN/AnA/AnU/FX) by serial communication when station No or PC No was set more than 10 |
|
Ver3.00 (Build2) - 2004 Jun. |
| 1230111 |
ALL |
Startup Tag file setting of Start Up(Tools menu -> Option) is not kept |
|
Ver3.00 (Build1) - 2004 Feb. - Apr. |
| 1230000 |
ALL |
Compatible with OPCDA3.0 |
| ------ |
ALL |
Renewal GUI (menu, toolbar, dialog or something) |
| ------ |
ALL |
Monitor the status accessing from OPC Client |
| ------ |
ALL |
Added the default simulation pattern |
| ------ |
ALL |
Modified the tag registered operation |
| ------ |
ALL |
Display the detail information and sort function of logged data is added |
| ------ |
ALL |
Auto save function for logged information is added |
| ------ |
ALL |
Supply the .NET Framework sample |
|
Ver2.42 (Build7) - 2004 Feb. |
| 1224258 |
ALL |
Fixed the tag registered automatically doesn't monitor the value |
| 1224260 |
ALL |
Change the auto naming rule on automatically added |
| 1224263 |
ALL |
Modified the action on poke error happened |
| 1224266 |
ALL |
Modified to poke process when mixed word devices and double word devices |
| ------ |
ALL |
Update OPC common files |
| 1224259 |
MELSEC |
Fixed to register the invalid address for the tag under 32767 when auto-registration with 'ZR' |
| 1224267 |
MELSEC |
Fixed to be not able to input network number in device dialog with interface board |
| 1224262 |
FA-M3 |
Fixed to be not able to change COM port number |
|
Ver2.42 (Build6) - 2003 Jul. |
| 1224234 |
ALL |
Fixed to return invalid value for reading after poking to scale convert tag or BCD convert tag. |
| 1224246 |
ALL |
Fixed to sometime occur memory leak when execute AsyncRead to string or array tags |
| 1224250 |
ALL |
Modified IOPCItemProperties::LookupItemIDs interface action |
| 1224254 |
ALL |
Modified Async2::Refresh2 interface action |
| 1224253 |
ALL |
Modified to call IOPCDataCallback::OnCancelComplete after Async2::Cancel2 |
| 1224252 |
ALL |
Modified IOPCItemProperties::GetItemProperties interface action |
| 1224239 |
FA-M3/ TOYOPUC |
Fixed to occur error by Read/Write operation just after Additem |
| 1224236 |
SYSMAC |
Fixed that the change of read span is not reflect on device dialog |
| 1224237 |
SYSMAC |
Modified to be suited poke action on continuous access range |
|
Ver2.42 (Build5) - 2003 May. |
| 1224232 |
ALL |
Fixed to return error even when be successful with poking into array tag. (Bug of Ver2.42 Build4) |
| 1224233 |
ALL |
Modified to generate the data-change event on completing poke action |
|
Ver2.42 (Build4) - 2003 Apr. |
| 1224226 |
ALL |
Fixed to be stopped automatic re-connection on TCP/IP Full-Passive communication |
| 1224228 |
ALL |
Fixed to be not able to change the name of OPC Group Name on active from OPC Client |
|
Ver2.42 (Build3) - 2003 Mar. |
| 1224223 |
ALL |
Fixed to be not able to connect again after happening communication error on Ethernet. (Bug of Ver2.42 Build1 / Build2) |
|
Ver2.42 (Build2) - 2003 Feb. |
| 1224222 |
ALL |
Fixed to be not able to poke to Array tags. (Bug of Ver2.42 Build1) |
| 1224224 |
MELSEC |
Modified SPIN button keeps disable |
|
Ver2.42 (Build1) - 2003 Jan. |
| 1224200 |
ALL |
Certificated compliance test - OPCDA 2.05A |
| 1224203 |
ALL |
Expanded max of port from 64 to 128 |
| 1224204 |
ALL |
Modified to be able to select whether attached '$' mark with system tags |
| 1224205 |
ALL |
Changed rule of tag name generation |
| 1224206 |
ALL |
Added 'Simulate' in system tag |
| 1224207 |
ALL |
Change menu resource |
| 1224208 |
ALL |
Modified to idle time when Ethernet open error occurred |
| 1224210 |
ALL |
Fixed to be not able to back when select Square Root in scaling |
| 1224211 |
ALL |
Fixed to be not able to load normally if comments include ',' |
| 1224212 |
ALL |
Fixed to be shown the value '??' on monitor when array tag imported |
| 1224213 |
ALL |
Fixed scaling configuration is not available while communicating |
| 1224214 |
ALL |
Fixed bandwidth value is invalid |
| 1224215 |
ALL |
Fixed to re-bind when open error occurred |
| 1224218 |
MELSEC |
Fixed to be written '-1' if serial communication with AnN/FX CPU |
| 1224216 |
FAM3 /SYSMAC |
Fixed to be not shown ':U' on unsigned short tag |
| 1224217 |
SYSMAC |
Fixed to be not shown ':R' on real tag |
| 1224209 |
SYSMAC |
Modified bank range '0 - 28' |
| 1224219 |
SYSMAC |
Modified EDIT button is disable with FINS port |
| ------ |
SYSMAC |
Fixed available spin button in tag dialog |
| 1224220 |
ALL |
Modified to be not as error while FINS communicating when sub code returned except '0' from FinsGateway |
|
Ver2.41 (Build1) - 2002 Jul. - Oct. |
| ------ |
ALL |
Fixed bandwidth will be invalid value |
| ------ |
ALL |
Fixed to be happened memory leak when read/write operation with deactivate OPC group |
| ------ |
ALL |
Windows XP compatible |
| ------ |
ALL |
Run as windows service program |
| ------ |
ALL |
Duplex communication port |
| ------ |
ALL |
System information tag |
| ------ |
ALL |
Poking from OPC Server window |
| ------ |
ALL |
Auto Creating message files |
| ------ |
ALL |
Fixed to leak memory on AsyncPoke() with string type |
| ------ |
ALL |
Modified to be not able to access tag after poking abnormal value with variant type from VB |
| ------ |
ALL |
Modified to be not able to get OPCItem properties of scale convert |
| ------ |
FAM3 |
Supported Ethernet unit LE11-0T |
| ------ |
SYSMAC |
Supported native communication of serial and Ethernet. (Not use FINS Gateway) |
| ------ |
MELSEC |
On Ethernet communication, CPU monitoring timer was changed to 10 sec from 2 sec |
| ------ |
MELSEC |
Fixed to be able to access scale property for not configured tags |
|
Ver2.30 (Build6 : MELSEC / Build4 : FAM3, SYSMAC / Build10 : TOYOPUC) - 2002 Aug. |
| ------ |
ALL |
Modified to return exception with invalid server handle on SyncRead |
| ------ |
SYSMAC |
Bank number of expanded EM to maximum 12 |
| ------ |
SYSMAC |
Fixed header title is out of position on device export |
|
Ver2.30 (Build5) - 2002 May. |
| ------ |
MELSEC |
Fixed to be fail on batch poke to bit device with MELSEC interface boards |
| ------ |
MELSEC |
Scale conversion will be fail for negative value |
|
Ver2.30 (Build4 : MELSEC / Build3 : FAM3, SYSMAC / Build9 : TOYOPUC) - 2002 Feb. |
| ------ |
ALL |
Application error will be happened on Port dialog (Ethernet) |
| ------ |
ALL |
Change to return normally when execute Read/Write operation while connecting Ethernet without OPC_QUALITY_COMM_FAILURE. |
| ------ |
ALL |
Fixed header title is out of position on device export. |
|
Ver2.30 (Build3) - 2001 Dec. |
| ------ |
MELSEC |
Fixed to be happened application error when timeout error occurred on connecting MELSEC-Q/QnA Ethernet. |
| ------ |
MELSEC |
Fix to register special relay 'SM' and special register 'SD' |
|
Ver2.30 (Build2) - 2001 Aug. |
| ------ |
ALL |
Supported with unsigned integer (VT_UI2 / VT_UI4) |
| ------ |
ALL |
Supported with array type, VT_ARRAY : VT_BOOL / VT_I2 / VT_UI2 / VT_I4 / VT_UI4 / VT_R4 |
| ------ |
ALL |
Fixed to be poked the previous value of conversion to scaled tag |
| ------ |
ALL |
IP address will be changed to invalid value when jump from device configuration dialog |
| ------ |
MELSEC |
Supported MELSEC multi CPU system |
| ------ |
MELSEC |
Supported CONTEC PC unit (PPC-CPU) |
| ------ |
MELSEC |
Supported user setting on batch poke points |
| ------ |
MELSEC /FAM3 |
Supported to access bit device as real type tag |
| ------ |
SYSMAC |
Supported to access 'D' as 'DM' |
| ------ |
SYSMAC |
Modified to swap upper byte and lower byte of string tag |
|
Ver2.24 (Build1) - 2001 Jan. |
| ------ |
ALL |
Change Device dialog |
| ------ |
ALL |
Added button to configuration the communication port on device dialog |
| ------ |
ALL |
Modified to get BCD configuration on imported tag |
| ------ |
ALL |
Certificated compliance test - OPCDA 1.0 |
| ------ |
ALL |
Modified OPCDAAuto.dll (Update 'OPCDAAuto.dll' because can't configure the Updaterate on Windows 2000) |
| ------ |
FAM3 |
When using Binary communication on Ethernet, the poke operation to DWORD/REAL will be failed |
|
Ver2.23 (Build1) - 2000 Oct. |
| ------ |
ALL |
Fixed the retry function is executed an extra time |
| ------ |
ALL |
Fixed to read the data abnormal when some device in some groups is registered for one group.
(ex : Group1 <<-- UC24.D0 Ether.M0 MENT.W0...) |
| ------ |
ALL |
Fixed the error checking routine of some OPC interface |
| ------ |
ALL |
Fixed to return 'OPC_S_CLAMP' when written data to over size for string tags |
| ------ |
ALL |
Standardize the declaration of static pattern for simulation function to 'dummy' |
| ------ |
ALL |
the string tag for simulation mode is improved to be changed the value |
| ------ |
ALL |
Fixed to be not able to store in task tray when starting with remote client |
| ------ |
FAM3 |
Fixed to be not able to access to the device over 32768 |
| ------ |
MELSEC |
Standardize the declaration of 'random read' to 'block access' |
| ------ |
MELSEC |
Fixed to not show the log message when accessing to bit type device |
| ------ |
MELSEC |
Fixed to be set irregular string size when registering bit type tag in dialog |
| ------ |
MELSEC |
Improve the random write size to 1024 when using MELSEC Interface board |
|
Ver2.22 (Build1) - 2000 Jan. |
| ------ |
SYSMAC |
OMRON SYSMAC OPC Server release |
| ------ |
FAM3 |
YOKOGAWA FA-M3 OPC Server release |
| ------ |
MELSEC |
Enable to select priority of thread and process |
| ------ |
MELSEC |
Enable to access to other groups within executing much SyncRead operation |
| ------ |
MELSEC |
Progress bar on import/export tag |
| ------ |
MELSEC |
Progress bar on edit tag |
| ------ |
MELSEC |
Open configuration dialog on Double click at Device name |
| ------ |
MELSEC |
Communicate only displayed tags While monitoring on screen |
| ------ |
MELSEC |
Store in task tray on minimize operation |
| ------ |
MELSEC |
A display place of 'D', 'R', 'ER' change to 5 |
| ------ |
MELSEC |
Change find algorithm on registered item |
|
Ver2.21 (Build1) - 2000 Feb. |
| ------ |
MELSEC |
Supported random read operation |
| ------ |
MELSEC |
Supported CPU port and LLT with MX-Links (SWnD5C-CSKP) |
| ------ |
MELSEC |
Supported CC-Link Master Board (A80BD-J61BT11) |
| ------ |
MELSEC |
Fixed disappear tips on task tray |
|
Ver2.20 (Build3) - 1999 Dec. |
| ------ |
MELSEC |
Fixed percentage of CPU is to 100 if OPCItem is continuously valid and invalid |
|
Ver2.20 (Build2) - 1999 Nov. |
| ------ |
MELSEC |
Fixed not release memory of string tag accessing |
|
Ver2.20 (Build1) - 1999 Aug. |
| ------ |
MELSEC |
Supported MELSEC-Qn Series |
| ------ |
MELSEC |
Supported Bit position read in word device |
| ------ |
MELSEC |
Supported String and BCD type |
| ------ |
MELSEC |
Enabled to select configuration file on startup |
| ------ |
MELSEC |
Enabled to select data type on tag edit |
| ------ |
MELSEC |
Communication port dialog |
| ------ |
MELSEC |
Enabled to select group level on import/export tag |
| ------ |
MELSEC |
Support import/export function |
|
Ver2.10 (Build2) - 1999 Aug. |
| ------ |
MELSEC |
Fixed normally start without Administrator of WinNT |
|
Ver2.10 (Build1) - 1999 Jul. |
| ------ |
MELSEC |
Supported MELSEC Interface Board for personal computer |
| ------ |
MELSEC |
Supported multiple LAN adapter |
| ------ |
MELSEC |
Supported any COM port without limited |
| ------ |
MELSEC |
Supported import/export function of tag |
| ------ |
MELSEC |
Supported dump of communication log |
| ------ |
MELSEC |
Supported dump of OPC interface access log |
| ------ |
MELSEC |
Supported export log to text file |
| ------ |
MELSEC |
Supported store to task tray |
| ------ |
MELSEC |
Supported word access of bit device |
| ------ |
MELSEC |
Supported user configuration of retry times on timeout |
| ------ |
MELSEC |
Supported user configuration of packet size on batch reading |
| ------ |
MELSEC |
The 'Type' in Tag View is changed from the Device name to the Data type |
| ------ |
MELSEC |
Supported auto shutdown function |
| ------ |
MELSEC |
Fixed stop bit is not available on serial communication |
|
Ver2.00 (Build1) - 1999 Feb. |
| ------ |
MELSEC |
Supported OPCDA2.0 |
| ------ |
MELSEC |
Deleted WORD SWAP selection |
| ------ |
MELSEC |
Supported auto addition of item |
| ------ |
MELSEC |
Enable to force shout down while client is connecting |
| ------ |
MELSEC |
Supported continuous tag entry |
| ------ |
MELSEC |
Supported Expand File Register |
| ------ |
MELSEC |
Fixed application error on item removing |
|