Forward |
This information is about bug or new function, and supplied for promoting user integration
|
| DeviceXPlorer OPC Server DXP2007 series |
| 1240151 |
ALL |
The memory leak might occur when the string tags is accessed in simulation mode. |
| 1240152 |
ALL |
The application error might be generated in communication processing with PLC. |
| 1240153 |
ALL |
The application error might be generated by the checking processing of license information. |
| 1240143 |
ALL |
It might take time to respond when asynchronize request is executed two or more times while the communication error. |
| 1240137 |
ALL |
It is displayed, the project name is "Untitled" when starting. |
| 1240140 |
ALL |
The change of the application name of DDE/SuiteLink doesn't become effective. |
| 1240141 |
ALL |
If writing is executed through DDE/SuiteLink interface, CPU utilization might become higher. |
| 1240142 |
ALL |
The application error might be generated when a specific click operation is done by the device view. |
| 1240121 |
MELSEC |
Fix the issue that the Message Error occurs when block access command is used. |
| 1240122 |
MELSEC |
Fix the issue that the value of buffer memory (G) read of special unit is not appropriate. |
| 1240125 |
SYSMAC |
Fix the issue that bank number accesses 0 even if other bank number is specified when extended data memory (EM) is accessed. |
| 1240126 |
SYSMAC |
Fix the issue that the Message Error occurs when Timer and Counter (TC/CC)contact is read. |
| 1240127 |
SYSMAC |
Fix the issue that the value can be written to byte-type tag (read only) from OPC client. |
| 1240128 |
ALL |
Fix the issue that the error occurs when the value is written in hexadecimal number of the small letter in tag view. |
| 1240129 |
MELSEC |
Fix the issue that the write processing failed when it communicates with ACPU in format 4. |
| 1240131 |
MELSEC |
Fix the issue that NAK Receive Error occurs when QnACPU is selected. |
| 1240132 |
MELSEC |
Fix the issue that the write value of word device is not appropriate when block access command is used. |
| 1240133 |
ALL |
The start processing about minimization and task tray are improved. |
| 1240120 |
FA-M3 |
Fix the issue that the value is wrong in the continuous bit device read. |
| 1240123 |
All |
Fix the issue that the handle leak occurs when Ethernet port open is error. |
| 1240110 |
KV |
All KV5000 series is supported (Supported KV-LE20V Protocol). |
| 1240111 |
MICREX |
The write command of bit unit is supported. |
| 1240100 |
ALL |
Fix the issue that the non-changed items is notified by DataChange event. |
| 1240101 |
SYSMAC |
Fix the issue that the value is wrong, in the bit read of the word device. |
| 1240102 |
MELSEC |
Fix the issue that "Auto Change Route" is wrong when it is saved, in the port dialog. |
| 1240103 |
MELSEC |
Fix the issue that "Unit I/O No." in "Multiple CPU System" is wrong when it is saved, in the device dialog. |
| 1240104 |
ALL |
Fix the issue that the error occurs when the value is written in hexadecimal number of the small letter, in tag view. |
| 1240105 |
FA-M3 |
Fix the issue that the Message Error occurs when array-type tag of bit device is read. |
| 1240106 |
HIDIC |
Fix the issue that the access point can be set exceeding the maximum value, when EH-CPU is selected. |
| 1240107 |
MELSEC |
Fix the issue that the error don't occur, when the abnormal message is recieved in connecting FXCPU. |
| 1240112 |
MODBUS KV FA-M3 SATELLITE |
Fix the issue that the PLC device name for Connection Test is not appropriate. |
| 1240114 |
ALL |
Fix the issue that the displaying such as message output is not appropriate, about the platform license. |
| 1240116 |
FA-M3 |
Fix the issue that the Timer and Buffer Memory can be added to server, in using Asyncronous Access. |
| 1240117 |
ALL |
Fix the issue that the error occurs, when "Find" function is used in the Diagnostics View. |
| 1240115 |
ALL |
The restriction of demo version that can use only one device type (for example only "D" register) is removed. |
| 1240118 |
ALL |
The method how to permute tag in Diagnostics View is improved.(in Tag Name order -> in Tag Path order) |
| ----- |
ALL |
OPCClient.exe is updated. (Version 3.06) |
| ----- |
ALL |
OPC Core Components 3.00 file is updated. (3.00.1.02) |
| 1240108 |
ALL |
OPC Compliance Test 2.0.13 is passed. (DA2.05A 2.0.17/DA3.0 1.0.13) |
| 1240113 |
MODBUS |
The configuration file of waveform module (type 2321) and multiple module (type 2306) of HIOKI 2300 series are added. |
| 1231220 |
ALL |
When the tag of simulation mode is enabled and its patturn is "Dummy", even the value that is out of range is written to tags with the scale conversion enabled. |
| 1231221 |
ALL |
Every time the value of tag with the scale conversion enabled is read, time stamp and quality flag are updated. |
| 1231220 |
ALL |
Changed to return S_OK when the item name was specified by IOPCBrowse::Browse. |
| DeviceXPlorer OPC Server Ver.3 series |
| |
Ver3.12 (Build3) - 2007 Mar. |
| |
Ver3.12 (Build2) - 2006 Nov. |
| 1231206 |
MELSEC |
Registerd items as "Z" in OPC Server, when they are registerd as device name "T", "C", "S", "E" from OPC Client.(Correspond Version 3.12 Build1) |
| |
Ver3.12 (Build1) - 2006 Nov. |
| 1231203 |
ALL |
Add these following settings.
# Reject unregistered items (Reject access to unregistered items in OPC Server from OPC Client.)
# Hide system tag. (Do not show system tag on tag view.) |
| 1231204 |
ALL |
Add the setting on tag dialog.
# Access right (set right to access from OPC Client.) |
| 1231205 |
MELSEC |
Support Special Link(SB), Link Special Register(SW), Edge Relay(V), and Index Register(Z). |
| |
Ver3.11 (Build5) - 2006 May |
| 1231128 |
ALL |
Changed to switch the simulation mode to Enabled/Disabled by changing the System tag $Simulate switched to ON/OFF. |
| 1231138 |
ALL |
Changed to display the device name and group name in ascending order in the device view. |
| 1231140 |
ALL |
Add to show the error code into OPC interface log |
| 1231157 |
ALL |
Add the delay time setting in the serial port configuration to delay sending commands to PLC. |
| 1231133 |
ALL |
Cannot use the serial port of COM10 and more. |
| 1231134 |
ALL |
Modified to return expception error when called IOPCAsyncIO2::Refresh2 |
| 1231137 |
ALL |
Modified to be refused the AddItem method while openning the new device dialog |
| 1231145 |
ALL |
Fix the issue not to update the Quality by communication error |
| 1231146 |
ALL |
Fix the issue to stop updating display when much messages is put into LogView. |
| 1231156 |
ALL |
Fix the issue that it may occur the application error when it is selected "Tag" in "Project" menu if the device does not exist |
| 1231161 |
ALL |
Fix the issue that changine value is ignored by open/close scaling dialog |
| 1231162 |
ALL |
When the value is out of the range of scale conversion, it will not be stored in the item.(Correspond Version 3.10 Build2-3.11 Build4) |
| 1231163 |
ALL |
When simulating the array type tags of VT_I4, VT_UI4 and VT_R4, random values were returned even with the ramp simulation pattern specified. |
| 1231164 |
ALL |
When browsing OPC Items with OPC Client, tags with the scale conversion enabled is filtered not by the VT_R8 but by the non scale converted data type. |
| 1231147 |
ALL |
Changed to create log files with the date and file serial numbers (000 - 999). Also changed to set the maximum file size in MB (in previous version, in KB). |
| ------- |
ALL |
Updated OPC Core Components 2.00 Files(2.00.2.30) |
| ------- |
ALL |
Updated OPC DA Automation DLL Files(2.02.5.30) |
| ------- |
ALL |
Passed OPC Compliance Test 2.00.10.1130(DA2.05A 2.00.13/DA3.0 1.00.9) |
| |
Ver3.11 (Build4) - 2005 Nov. |
| 1231119 |
HIDIC |
Corresponded EHV-CPU |
| |
Ver3.11 (Build3) - 2005 Sep. |
| 1231111 |
ALL |
Changed writing has an advantage over reading.(Correspond Version 3.10 Build2-3.11 Build2) |
| |
Ver3.11 (Build2) - 2005 July. |
|
1231103 |
ALL |
Sometimes last
item misses to be written when items that belong to
different devices exist.(Correspond Version Ver3.01
Build1-Ver3.11 Build1) |
|
1231105 |
ALL |
Added OPC Client
name in OPC access log. |
| |
Ver3.11 (Build1) - 2005 May. |
| 1231100 |
ALL |
Changed the install license authentication |
| 1231102 |
ALL |
Changed the description of ProgID and service name to "DeviceXPlorer
XXXXXX OPC Server". |
| |
Ver3.10 (Build3) - 2005 May. |
| 1231064 |
ALL |
Changed the return NULL for IOPCItemProperties::LookupItemIDs and IOPCBrowse::GetProperties when idsuffix was referred. |
| 1231065 |
ALL |
Memory leak occurs when tag monitor is executing.(Correspond Version 3.10 Build1/Build2) |
| 1231067 |
ALL |
Event of KeepAlive (OnDataChange) is not notified when the item is invalidated. |
| 1231069 |
ALL |
Memory leak occurs when OPCGroup that has inactive OPCItem is deleted.(Correspond Version 3.10 Build1/Build2) |
| 1231071 |
ALL |
Array type tag of VT_I2 / VT_UI2 operate in the simulation mode of tag even if one of the device is set to priority. |
| 1231072 |
FA-M3 |
Device range of L and W device is expanded to 8192 from 2048 |
| 1231073 |
ALL |
Changed the return value to OPC_E_INVALIDITEMID from OPC_E_UNKNOWNITEMID for IOPCBrowse::GetProperties when item could not be found. |
| ------- |
ALL |
Updated OPC DA Automation DLL File (2.02.5.20) |
|
Ver3.10 (Build2) - 2005 Feb. |
| 1231040 |
ALL |
Improved the IOPCBrowseServerAddressSpace::ChangeBrowsePosition interface when it was specified OPC_BROWSE_TO. |
| 1231047 |
ALL |
Supported BCD->BIN conversion with Array type data. |
| 1231051 |
ALL |
Write process become slow when write failure occurred with multiple device configuration. |
| 1231052 |
MELSEC |
Can not detect timeout on serial communication. (Correspond Version 3.10 Build1) |
| 1231056 |
MELSEC |
Array tag's data type can not change to client requested data type when IOPCAsyncIO Read was executed. (Correspond Version 3.10 Build1) |
| 1231057 |
ALL |
It is changed to return user definition value (0x00048000L) to ppErrors when a communication error occurs at the time of the Read. |
| 1231058 |
ALL |
Device icon left connecting even if communication is finished after it changes to standing by when the communication configured redundant setting. |
| 1231059 |
ALL |
An application error sometimes occurrs when log display paused and sorted the label. |
| 1231060 |
MELSEC |
It sometimes fails in the copy of OpcRcw.Da.dll at the time of the installation. |
| 1231062 |
ALL |
The date of the message in the log pane proceeds a day. |
| ------- |
ALL |
Updated OPC Core Components 2.00 Files(2.00.2.20) |
| ------- |
ALL |
Updated OPC DA Automation DLL Files(2.02.5.12) |
| ------- |
ALL |
Passed OPC Compliance Test 2.00.7.1120(DA2.05A 2.00.8/DA3.0 1.00.3) |
| ------- |
ALL |
Updated VB.NET Sample client (DotNetRcwSample) |
|
Ver3.10 (Build1) - 2004 Oct. |
| 1231014 |
ALL |
System information tag isn't added at the time of the device import |
| 1231001 |
ALL |
Supported new tag type that is always uses in the simulation mode |
| 1231000 |
ALL |
Supported OPCDA3.0 optional interface IOPCItemSamplingMgt |
| 1231002 |
ALL |
Supported Multi Access Mode (Supported independent operation of ports and groups) |
| 1231003 |
ALL |
The request queue for writing is canceled when write error occurred |
| 1231004 |
ALL |
Send error occurs when baud rate is low on serial communication |
| 1231006 |
ALL |
The maximum number of asynchronous requests modified 100 to 1000 |
| 1231008 |
ALL |
The port name during the communication is stored in the tag name "$Portname" |
| 1231020 |
ALL |
Improved the ItemIO::WriteVQT interface function when communication error occurred |
| 1231022 |
ALL |
Improved to hangs up in Ethernet port setting when the adaptor doesn't exist Ethernet |
| 1231017 |
ALL |
The default type of the CPU is changed to QCPU |
| 1231016 |
MELSEC |
EZSocket(include CPU Port and MELDAS)/GX Simulator communication are supported |
| 1231007 |
MELSEC |
Supported intelligent unit buffer memory access |
| 1231010 |
MELSEC |
The file register ZR is supported |
| 1231011 |
MELSEC |
Improved that it becomes an error of accessing block 0 of the file register when the interface board is used |
| 1231009 |
SYSMAC |
Supported Timer and Counter(current value and contact) |
|
Ver3.00 (Build3) - 2004 Jun. |
| 1230118 |
ALL |
OPC Server gave no response when it was edited or monitored after the new tag was imported |
| 1230119 |
MELSEC |
Could not communicate with MELSEC(AnN/AnA/AnU/FX) by serial communication when station No or PC No was set more than 10 |
|
Ver3.00 (Build2) - 2004 Jun. |
| 1230111 |
ALL |
Startup Tag file setting of Start Up(Tools menu -> Option) is not kept |
|
Ver3.00 (Build1) - 2004 Feb. - Apr. |
| 1230000 |
ALL |
Compatible with OPCDA3.0 |
| ------ |
ALL |
Renewal GUI (menu, toolbar, dialog or something) |
| ------ |
ALL |
Monitor the status accessing from OPC Client |
| ------ |
ALL |
Added the default simulation pattern |
| ------ |
ALL |
Modified the tag registered operation |
| ------ |
ALL |
Display the detail information and sort function of logged data is added |
| ------ |
ALL |
Auto save function for logged information is added |
| ------ |
ALL |
Supply the .NET Framework sample |
|
Ver2.42 (Build7) - 2004 Feb. |
| 1224258 |
ALL |
Fixed the tag registered automatically doesn't monitor the value |
| 1224260 |
ALL |
Change the auto naming rule on automatically added |
| 1224263 |
ALL |
Modified the action on poke error happened |
| 1224266 |
ALL |
Modified to poke process when mixed word devices and double word devices |
| ------ |
ALL |
Update OPC common files |
| 1224259 |
MELSEC |
Fixed to register the invalid address for the tag under 32767 when auto-registration with 'ZR' |
| 1224267 |
MELSEC |
Fixed to be not able to input network number in device dialog with interface board |
| 1224262 |
FA-M3 |
Fixed to be not able to change COM port number |
|
Ver2.42 (Build6) - 2003 Jul. |
| 1224234 |
ALL |
Fixed to return invalid value for reading after poking to scale convert tag or BCD convert tag. |
| 1224246 |
ALL |
Fixed to sometime occur memory leak when execute AsyncRead to string or array tags |
| 1224250 |
ALL |
Modified IOPCItemProperties::LookupItemIDs interface action |
| 1224254 |
ALL |
Modified Async2::Refresh2 interface action |
| 1224253 |
ALL |
Modified to call IOPCDataCallback::OnCancelComplete after Async2::Cancel2 |
| 1224252 |
ALL |
Modified IOPCItemProperties::GetItemProperties interface action |
| 1224239 |
FA-M3/ TOYOPUC |
Fixed to occur error by Read/Write operation just after Additem |
| 1224236 |
SYSMAC |
Fixed that the change of read span is not reflect on device dialog |
| 1224237 |
SYSMAC |
Modified to be suited poke action on continuous access range |
|
Ver2.42 (Build5) - 2003 May. |
| 1224232 |
ALL |
Fixed to return error even when be successful with poking into array tag. (Bug of Ver2.42 Build4) |
| 1224233 |
ALL |
Modified to generate the data-change event on completing poke action |
|
Ver2.42 (Build4) - 2003 Apr. |
| 1224226 |
ALL |
Fixed to be stopped automatic re-connection on TCP/IP Full-Passive communication |
| 1224228 |
ALL |
Fixed to be not able to change the name of OPC Group Name on active from OPC Client |
|
Ver2.42 (Build3) - 2003 Mar. |
| 1224223 |
ALL |
Fixed to be not able to connect again after happening communication error on Ethernet. (Bug of Ver2.42 Build1 / Build2) |
|
Ver2.42 (Build2) - 2003 Feb. |
| 1224222 |
ALL |
Fixed to be not able to poke to Array tags. (Bug of Ver2.42 Build1) |
| 1224224 |
MELSEC |
Modified SPIN button keeps disable |
|
Ver2.42 (Build1) - 2003 Jan. |
| 1224200 |
ALL |
Certificated compliance test - OPCDA 2.05A |
| 1224203 |
ALL |
Expanded max of port from 64 to 128 |
| 1224204 |
ALL |
Modified to be able to select whether attached '$' mark with system tags |
| 1224205 |
ALL |
Changed rule of tag name generation |
| 1224206 |
ALL |
Added 'Simulate' in system tag |
| 1224207 |
ALL |
Change menu resource |
| 1224208 |
ALL |
Modified to idle time when Ethernet open error occurred |
| 1224210 |
ALL |
Fixed to be not able to back when select Square Root in scaling |
| 1224211 |
ALL |
Fixed to be not able to load normally if comments include ',' |
| 1224212 |
ALL |
Fixed to be shown the value '??' on monitor when array tag imported |
| 1224213 |
ALL |
Fixed scaling configuration is not available while communicating |
| 1224214 |
ALL |
Fixed bandwidth value is invalid |
| 1224215 |
ALL |
Fixed to re-bind when open error occurred |
| 1224218 |
MELSEC |
Fixed to be written '-1' if serial communication with AnN/FX CPU |
| 1224216 |
FAM3 /SYSMAC |
Fixed to be not shown ':U' on unsigned short tag |
| 1224217 |
SYSMAC |
Fixed to be not shown ':R' on real tag |
| 1224209 |
SYSMAC |
Modified bank range '0 - 28' |
| 1224219 |
SYSMAC |
Modified EDIT button is disable with FINS port |
| ------ |
SYSMAC |
Fixed available spin button in tag dialog |
| 1224220 |
ALL |
Modified to be not as error while FINS communicating when sub code returned except '0' from FinsGateway |
|
Ver2.41 (Build1) - 2002 Jul. - Oct. |
| ------ |
ALL |
Fixed bandwidth will be invalid value |
| ------ |
ALL |
Fixed to be happened memory leak when read/write operation with deactivate OPC group |
| ------ |
ALL |
Windows XP compatible |
| ------ |
ALL |
Run as windows service program |
| ------ |
ALL |
Duplex communication port |
| ------ |
ALL |
System information tag |
| ------ |
ALL |
Poking from OPC Server window |
| ------ |
ALL |
Auto Creating message files |
| ------ |
ALL |
Fixed to leak memory on AsyncPoke() with string type |
| ------ |
ALL |
Modified to be not able to access tag after poking abnormal value with variant type from VB |
| ------ |
ALL |
Modified to be not able to get OPCItem properties of scale convert |
| ------ |
FAM3 |
Supported Ethernet unit LE11-0T |
| ------ |
SYSMAC |
Supported native communication of serial and Ethernet. (Not use FINS Gateway) |
| ------ |
MELSEC |
On Ethernet communication, CPU monitoring timer was changed to 10 sec from 2 sec¨X |
| ------ |
MELSEC |
Fixed to be able to access scale property for not configured tags |
|
Ver2.30 (Build6 : MELSEC / Build4 : FAM3, SYSMAC / Build10 : TOYOPUC) - 2002 Aug. |
| ------ |
ALL |
Modified to return exception with invalid server handle on SyncRead |
| ------ |
SYSMAC |
Bank number of expanded EM to maximum 12 |
| ------ |
SYSMAC |
Fixed header title is out of position on device export |
|
Ver2.30 (Build5) - 2002 May. |
| ------ |
MELSEC |
Fixed to be fail on batch poke to bit device with MELSEC interface boards |
| ------ |
MELSEC |
Scale conversion will be fail for negative value |
|
Ver2.30 (Build4 : MELSEC / Build3 : FAM3, SYSMAC / Build9 : TOYOPUC) - 2002 Feb. |
| ------ |
ALL |
Application error will be happened on Port dialog (Ethernet) |
| ------ |
ALL |
Change to return normally when execute Read/Write operation while connecting Ethernet without OPC_QUALITY_COMM_FAILURE. |
| ------ |
ALL |
Fixed header title is out of position on device export. |
|
Ver2.30 (Build3) - 2001 Dec. |
| ------ |
MELSEC |
Fixed to be happened application error when timeout error occurred on connecting MELSEC-Q/QnA Ethernet. |
| ------ |
MELSEC |
Fix to register special relay 'SM' and special register 'SD' |
|
Ver2.30 (Build2) - 2001 Aug. |
| ------ |
ALL |
Supported with unsigned integer (VT_UI2 / VT_UI4) |
| ------ |
ALL |
Supported with array type, VT_ARRAY : VT_BOOL / VT_I2 / VT_UI2 / VT_I4 / VT_UI4 / VT_R4 |
| ------ |
ALL |
Fixed to be poked the previous value of conversion to scaled tag |
| ------ |
ALL |
IP address will be changed to invalid value when jump from device configuration dialog |
| ------ |
MELSEC |
Supported MELSEC multi CPU system |
| ------ |
MELSEC |
Supported CONTEC PC unit (PPC-CPU) |
| ------ |
MELSEC |
Supported user setting on batch poke points |
| ------ |
MELSEC /FAM3 |
Supported to access bit device as real type tag |
| ------ |
SYSMAC |
Supported to access 'D' as 'DM' |
| ------ |
SYSMAC |
Modified to swap upper byte and lower byte of string tag |
|
Ver2.24 (Build1) - 2001 Jan. |
| ------ |
ALL |
Change Device dialog |
| ------ |
ALL |
Added button to configuration the communication port on device dialog |
| ------ |
ALL |
Modified to get BCD configuration on imported tag |
| ------ |
ALL |
Certificated compliance test - OPCDA 1.0 |
| ------ |
ALL |
Modified OPCDAAuto.dll (Update 'OPCDAAuto.dll' because can't configure the Updaterate on Windows 2000) |
| ------ |
FAM3 |
When using Binary communication on Ethernet, the poke operation to DWORD/REAL will be failed |
|
Ver2.23 (Build1) - 2000 Oct. |
| ------ |
ALL |
Fixed the retry function is executed an extra time |
| ------ |
ALL |
Fixed to read the data abnormal when some device in some groups is registered for one group.
(ex : Group1 <<-- UC24.D0 Ether.M0 MENT.W0...) |
| ------ |
ALL |
Fixed the error checking routine of some OPC interface |
| ------ |
ALL |
Fixed to return 'OPC_S_CLAMP' when written data to over size for string tags |
| ------ |
ALL |
Standardize the declaration of static pattern for simulation function to 'dummy' |
| ------ |
ALL |
the string tag for simulation mode is improved to be changed the value |
| ------ |
ALL |
Fixed to be not able to store in task tray when starting with remote client |
| ------ |
FAM3 |
Fixed to be not able to access to the device over 32768 |
| ------ |
MELSEC |
Standardize the declaration of 'random read' to 'block access' |
| ------ |
MELSEC |
Fixed to not show the log message when accessing to bit type device |
| ------ |
MELSEC |
Fixed to be set irregular string size when registering bit type tag in dialog |
| ------ |
MELSEC |
Improve the random write size to 1024 when using MELSEC Interface board |
|
Ver2.22 (Build1) - 2000 Jan. |
| ------ |
SYSMAC |
OMRON SYSMAC OPC Server release |
| ------ |
FAM3 |
YOKOGAWA FA-M3 OPC Server release |
| ------ |
MELSEC |
Enable to select priority of thread and process |
| ------ |
MELSEC |
Enable to access to other groups within executing much SyncRead operation |
| ------ |
MELSEC |
Progress bar on import/export tag |
| ------ |
MELSEC |
Progress bar on edit tag |
| ------ |
MELSEC |
Open configuration dialog on Double click at Device name |
| ------ |
MELSEC |
Communicate only displayed tags While monitoring on screen |
| ------ |
MELSEC |
Store in task tray on minimize operation |
| ------ |
MELSEC |
A display place of 'D', 'R', 'ER' change to 5 |
| ------ |
MELSEC |
Change find algorithm on registered item |
|
Ver2.21 (Build1) - 2000 Feb. |
| ------ |
MELSEC |
Supported random read operation |
| ------ |
MELSEC |
Supported CPU port and LLT with MX-Links (SWnD5C-CSKP) |
| ------ |
MELSEC |
Supported CC-Link Master Board (A80BD-J61BT11) |
| ------ |
MELSEC |
Fixed disappear tips on task tray |
|
Ver2.20 (Build3) - 1999 Dec. |
| ------ |
MELSEC |
Fixed percentage of CPU is to 100 if OPCItem is continuously valid and invalid |
|
Ver2.20 (Build2) - 1999 Nov. |
| ------ |
MELSEC |
Fixed not release memory of string tag accessing |
|
Ver2.20 (Build1) - 1999 Aug. |
| ------ |
MELSEC |
Supported MELSEC-Qn Series |
| ------ |
MELSEC |
Supported Bit position read in word device |
| ------ |
MELSEC |
Supported String and BCD type |
| ------ |
MELSEC |
Enabled to select configuration file on startup |
| ------ |
MELSEC |
Enabled to select data type on tag edit |
| ------ |
MELSEC |
Communication port dialog |
| ------ |
MELSEC |
Enabled to select group level on import/export tag |
| ------ |
MELSEC |
Support import/export function |
|
Ver2.10 (Build2) - 1999 Aug. |
| ------ |
MELSEC |
Fixed normally start without Administrator of WinNT |
|
Ver2.10 (Build1) - 1999 Jul. |
| ------ |
MELSEC |
Supported MELSEC Interface Board for personal computer |
| ------ |
MELSEC |
Supported multiple LAN adapter |
| ------ |
MELSEC |
Supported any COM port without limited |
| ------ |
MELSEC |
Supported import/export function of tag |
| ------ |
MELSEC |
Supported dump of communication log |
| ------ |
MELSEC |
Supported dump of OPC interface access log |
| ------ |
MELSEC |
Supported export log to text file |
| ------ |
MELSEC |
Supported store to task tray |
| ------ |
MELSEC |
Supported word access of bit device |
| ------ |
MELSEC |
Supported user configuration of retry times on timeout |
| ------ |
MELSEC |
Supported user configuration of packet size on batch reading |
| ------ |
MELSEC |
The 'Type' in Tag View is changed from the Device name to the Data type |
| ------ |
MELSEC |
Supported auto shutdown function |
| ------ |
MELSEC |
Fixed stop bit is not available on serial communication |
|
Ver2.00 (Build1) - 1999 Feb. |
| ------ |
MELSEC |
Supported OPCDA2.0 |
| ------ |
MELSEC |
Deleted WORD SWAP selection |
| ------ |
MELSEC |
Supported auto addition of item |
| ------ |
MELSEC |
Enable to force shout down while client is connecting |
| ------ |
MELSEC |
Supported continuous tag entry |
| ------ |
MELSEC |
Supported Expand File Register |
| ------ |
MELSEC |
Fixed application error on item removing |
|