Support all MELSEC ・・・PROCESS CONTROL,REDUNDANT SYSTEM, and MOTION SYSTEM also.


MELSEC

Support EZSocket
It is possible to configure the communication setting by the same screen as useful GX Works (GX Developer).
CSGL


Support L series/FX Ethernet/Stand-Alone Motion
Q170MCPU Support promptly new L series and FX series Ethernet. Support Q170MCPU of Stand-Alone Motion.


Equipped with "Q4E protocol" that controls packet gap
DeviceXPlorer doesn't happen the mismatch of response message and required message, because the Sequence number is embedded.
Q4E Protocol


Batch access function.
The more than one PLC register can be collectively read and written as separator string(slash "/") of a single tag. For example, when you add a OPCItem as "Device1.D0/D1000/ZR200/M0" , you can read "10351,23045,0,0".


Communication with random access buffer
Communicating shared memory of Ethernet unit by random access buffer, You can exchange datas high-speed , it doesn't depend on PLC's scan time.

Direct access to intelligent function module
Buffer memory"G" can only be accessed by groups for which the intelligent function module access is enabled. For example , When you select "QD75" and access to "G800", you can get "Current feed value".
BufferMemory


MELSECNET transient transfer
You can access to other CPU on MELSEC/H and CC-Link/IE via the Ethernet unit. You can construct flexible system configuration , but the communication performance is lower.
Transient Communication


Support multi CPU
You can access the device memory of the CPU among two or more CPU installed on Q bus. Because the transfer function between CPUs side is not used, the system construction of high throughput is possible.


Support a redundant system(QnPRHCPU)
It is possible to access CPU by specifying control system or standby system, system A or system B. By combining with the redundant function of the DeviceXPlorer, it is possible to correspond to the redundant system that automatically switches the line when the communication abnormality is generated.
Redundancy

View  Applicable Units CPU models and the Ethernet unit models that the OPC server is supported.
Diagnostics  Performnce A measurement of communication performance between OPC server and PLC.
View  GX-Works setting Explanation of Ethernet unit setting with PLC.


Support PLC


MELSEC
MITSUBISHI
MELSEC
SYSMAC
OMRON
SYSMAC
TOYOPUC
JTEKT
TOYOPUC
FA-M3
YOKOGAWA
FA-M3
HIDIC
HITACHI
HIDIC
SATELLITE
SHARP
SATELLITE
MICREX
FUJI
MICREX
FP Series
PANASONIC
FP-X
MP Series
YASUKAWA
MP2000
KV
KEYENCE
KV
ControlLogix
AB
ControlLogix
SIMATIC7
SIEMENS
SIMATIC
PMC
FANUC
PMC
MODBUS
MODBUS
OPC
OPCDA

OPC Server

DAServer

Products

Sales

Online Shop

Getting Help


About TAKEBISHI