KEYENCE KV setting
KEYENCE KV-5000 series Ethernet configuration.
To communicate with KV-5000 by Ethernet, It is necessary to configure the communication setting by KV STUDIO(KEYECNE'S Programing tool).
Network environment
This sample assume the following cases.
Host IP address:192.168.0.2
Host Port number:0
PLC IP address:192.168.0.1
PLC Port number:8501
Configuration of KV STUDIO
Explanation
- Open the unit editor of KV STUDIO, and you drag and drop "KV-LE20A" or "KV-LE20V" in the unit selection tab.
- It is not necessary to configure the communication setting in KV-5000(CPU Built-in Ethernet Port).
IP address and port number
Configure the Ethernet parameters such as IP address and port number etc. by the screen of unit setting.
Communication parameter
Explanation
- Configure IP address and port number in the property dialog.