HITACHI HIDIC device
HIDIC EH150-EHV series
device symbol
X (Input relay)
Y (Output relay)
R (Internal relay)
R (Special relay)
L (Link relay 1)
L (Link relay 2)
L (Link relay 3)
L (Link relay 4)
L (Link relay 5)
L (Link relay 6)
L (Link relay 7)
L (Link relay 8)
M (Internal relay)
DIF (Edge relay)
DFN (Edge relay)
TD (On delay timer)
TDN (Off delay timer)
SS (Single shot timer)
WDT (Watchdog timer)
MS (Monostable timer)
TMR (Totalizing timer)
CU (Up counter)
RCU (Ring counter)
CTU (Up down counter)
CTD (Up down counter)
CT (Up down counter)
CL (Passage value clear relay)
EX (Extended input relay)
EY (Extended output relay)
TM (Extended input relay)
WX (Input register)
WY (Output register)
WR (Internal register)
WR (Special register)
WL (Link register 1)
WL (Link register 2)
WL (Link register 3)
WL (Link register 4)
WL (Link register 5)
WL (Link register 6)
WL (Link register 7)
WL (Link register 8)
WM (Internal register)
TC (Timer / counter current value)
WN (Internal output)
TV (Extended timer passage value)
WEX (Extended input register)
WEY (Extended output register)
Comment
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
shared
leading
trailing
up input
down input
down output
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
shared
for FL-net
* An accessible range of the device depends on the setting of PLC.
HIDIC EH150 series
Device symbol
X (Input relay)
Y (Output relay)
R (Internal relay)
R (Special relay)
L (Link relay 1)
L (Link relay 2)
M (Internal relay)
DIF (Edge relay)
DFN (Edge relay)
TD (On delay timer)
TDN (Off delay timer)
SS (Single shot timer)
WDT (Watchdog timer)
MS (Monostable timer)
TMR (Totalizing timer)
CU (Up counter)
RCU (Ring counter)
CTU (Up down counter)
CTD (Up down counter)
CT (Up down counter)
CL (Passage value clear relay)
TM (Extended timer)
WX (Input register)
WY (Output register)
WR (Internal register)
WR (Special register)
WL (Link register 1)
WL (Link register 2)
WM (Internal register)
TC (Timer / counter current value)
WN (Internal output)
TV (Extended timer passage value)
Comment
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
shared
leading
trailing
Up input
Down input
Down output
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
shared
for FL-net
* An accessible range of the device depends on the setting of PLC.
HIDIC H series
Device symbol
X (Input relay)
Y (Outpu relay)
R (Internalrelay)
R (Special relay)
L (Link relay 1)
L (Link relay 2)
M (Internal relay)
DIF (Edge relay)
DFN (Edge relay)
TD (On delay timer)
TDN (Off delay timer)
SS (Single shot timer)
WDT (Watchdog timer)
MS (Mono stable timer)
TMR (Totalizing timer)
CU (Up counter)
RCU (Ring counter)
CTU (Up down counter)
CTD (Up down counter)
CT (Up down counter)
CL (Passage value clear relay)
WX (Input register)
WY (Output register)
WR (Internal register)
WR (Special register)
WL (Link register 1)
WL (Link register 2)
WM (Internal register)
TC (timer/counter current value)
WN (Internal output)
Comment
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
shared
leading
trailing
Up input
Down input
Down output
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
Devie number:Remote number(1digit)+unit number(1digit)+slot position(1digti)+bit number(2digit)
shared
for FL-net
* An accessible range of the device depends on the setting of PLC.